Factory production - intelligent closed flash point / closed flash point automatic analyzer

Factory production - intelligent closed flash point / closed flash point automatic analyzer

1+
7600 CNY (1106.59USD)
52+
7500 CNY (1092.02USD)

add to cart

Product parameters:

  • Customization: Yes
  • Type: ion tester
  • Brand: Yu De
  • Model: YD
  • Measuring range: room temperature ~ 350 ℃
  • Measured sample status: 500 analysis results can be stored
  • Repeatability error:> 110 ℃ ± 2 ℃ ≤110 ℃ ± 1 ℃
  • Dimensions: 400mm × 440mm × 630mm
  • Scope: room temperature ~ 350 ℃






YD8847 YD8848 VKK3000 VBK3001Open flash point automatic analyzer:


VKK3000 automatic opening flash point detector is a self-developed with the leading domestic level of high-tech products (can be oil flash point, flash detection) flash detection device using patented technology, the use of high-performance detection of the ion ring on the flame conductive resistance Value of the mutation to detect, this detection method and the flame when the direction of ion movement consistent with the expansion of the detection surface to improve the sensitivity and to avoid the missed, false and other phenomena.
The use of high-definition color touch screen technology; with self-test function; data storage capacity, can store 500 data; the use of high-definition color display technology; Platinum igniter, atmospheric pressure automatic correction, long life, ignition stability.

Innovative Technology:
The external lighter brightness adjustment knob solves the problem of inaccurate test results caused by the aging of the igniter after prolonged use.

Technical indicators:
★ meet the standard: GB / T3536-2008 GB / T267-2008
★ display: high-definition color touch screen
★ range: room temperature ~ 400 ℃
★ Resolution: 0.1 ℃
★ Accuracy: ± 2 ℃
★ Repeatability: ± 3 ℃
★ Ambient temperature: 5 ~ 40 ℃
★ relative humidity: 10% to 80%
★ Power: AC220V ± 10% 50Hz ± 5%
★ Power: 550W


YD8847 YD8848 VKK3000 VBK3001

VBK3001 closed flash point automatic analyzer is developed with the leading domestic level of high-tech products, the instrument closed-loop control technology to achieve a good control of the heating rate; the use of air-cooled devices, rapid cooling cooling; high-resolution color touch screen Display; test over-temperature alarm and automatically stop the experiment; 32-bit single-chip microcomputer automatic control of heating, stirring, flashing the whole process; with self-test function; data storage capacity (to store 500 data records); atmospheric pressure correction, End the automatic display and print the measurement results.

Innovative Technology:
The external lighter brightness adjustment knob solves the problem of inaccurate test results caused by the aging of the igniter after prolonged use.

Technical indicators:
★ meet the standard: GB / T261-2008 ASTM D93
★ display: high-definition color touch screen
★ range: room temperature ~ 350 ℃
★ Resolution: 0.1 ℃
★ Repeatability: Flash point value ≤ 110 ℃ ± 1 ℃ Flash point value> 110 ℃ when ± 2 ℃
★ Ambient temperature: 5 ~ 40 ℃
★ relative humidity: 10% to 80%
★ Power: AC220V ± 10% 50Hz ± 5%
★ Power: 350W