Inflatable test transformer / sulfur hexafluoride gas SF6 | high pressure withstand voltage test device | AC direct current

Inflatable test transformer / sulfur hexafluoride gas SF6 | high pressure withstand voltage test device | AC direct current

8500 CNY (1237.63USD)

add to cart

Product parameters:

  • Voltage ratio: 1
  • Power phase: single phase
  • Rated power: 2
  • Moisture way: open type
  • Cooling method: other
  • Cooling form: inflatable
  • Frequency characteristics: high frequency
  • Brand: Yu De
  • Winding form: double winding
  • Core form: ring
  • Core shape: ring type
  • Outline structure: vertical
  • Efficiency (η): 3
  • Model: YD
  • Rated voltage: 50
  • Rated current: 3
  • Product Certification: 4




product description

The test of high voltage test transformer is the necessary test equipment for the detection and preventive test of electric power equipment.With the development of electric power industry in our country, the voltage level of the test transformer is getting higher and higher, and the oil insulation test transformer is in volume and weight (SF6) to the application area of ​​electric power equipment.With the development of basic science research, the application of new materials and new technology, the new insulating medium SF6 gas is pushed into the field of electric power equipment application. Fluoride gas good insulation and arc performance, and non-flammable, making it as a new insulating medium to be widely used power system.

I plant after years of efforts to study the success of the inflatable ultra-light test transformer, the product compared with the oil-immersed test transformer with small size, light weight, no oil pollution, from climate change, corona extremely small Advantages, a single voltage up to 300KV.

Product parameters

● Input voltage: 10kVA and below AC200V
10kVA or more for the AC400V
● No load loss: < 10%
● Short circuit impedance: < 10%
● Change ratio error: < 1%
● Instrument voltage: 100V

model

Input voltage

The output voltage

Low voltage current

High voltage current

Dimension (mm)

Weight (kg)

3/50

AC200V

50kV

15A

60mA

Φ300 × 690

35

5/50

25A

100mA

Φ300 × 690

35

10/50

50A

200mA

Φ375 × 750

60

15/50

AC400V

37.5A

300mA

Φ420 × 800

70

20/50

50A

400mA

Φ440 × 820

85

30/50

75A

600mA

Φ386 × 840

100

50/50

125A

1000mA

Φ416 × 910

120

5/100

AC200V

100kV

25A

50mA

Φ300 × 1300

65

10/100

50A

100mA

Φ475 × 1300

65

15/100

AC400V

37.5A

150mA

Φ390 x 1320

85

20/100

50A

200mA

Φ400 × 1340

100

30/100

75A

300mA

Φ410 × 1360

110

50/100

125A

500mA

Φ460 × 1410

125

15/150

150kV

37.5A

100mA

Φ390 × 1800

100

20/150

50A

133mA

Φ415 × 1800

110

30/150

75A

200mA

Φ430 × 1800

125

50/150

125A

333mA

Φ490 × 1850

140

20/200

200kV

50A

100mA

Φ510 × 2150

140

30/200

75A

150mA

Φ530 × 2150

160

50/200

125A

250mA

Φ550 × 2150

240

Equipment protection

1) Keep the equipment clean.

2) regularly check the equipment pressure, found that leakage should be promptly contact with the factory.

3) When the air pressure ≤ 0.2Mpa, it should be timely qi.

4) equipment transport not allowed to tap.

Equipment Repair

Equipment from the factory the following three years to implement the following three packs:

High voltage coil short circuit or breakdown.

2. Low voltage coil short circuit or burned.

3. The shell is not well leaked.

4. All faults caused by product quality.

5. Instrument coil burned out of the scope of the three packs.

Precautions

1. Current limiting resistor setting, power frequency withstand voltage by 0.5 ~ 1Ω / V, DC test by 5 ~ 10Ω / V. The size of the resistance can be distilled water, water and salt in different proportions of deployment.

2. In the case of high-voltage output, and the high-pressure side without any load conditions, is strictly prohibited directly disconnect the power, should first drop the regulator to zero and then disconnect the power.