bargain
add to cart
Explanation
① basic error is better than ± 0.2% F · S, 16 bit A / D converter, measurement and control cycle 0.2 seconds, self-tuning
② anti-jamming design, inhibit the rapid burst interference relays, contactors, etc. produced by the scene and other electromagnetic interference, immunity to level III
③ Input signal: thermal resistance, thermocouple, DC current, DC voltage, remote pressure gauge, etc.
④ Dimensions: 160 * 80 (horizontal / vertical), 96 * 9696 * 48 (horizontal / vertical), 72 * 7248 * 48
⑤ Instrument Power: 220V AC (9 ~ 30) V DC.
⑥ hand / auto switch
basic configuration
Dual display and control output
extensions
① alarm output: 160 * 8096 * 9696 * 48 in three sizes can add up to 3:00; 72 * 7248 * 48 may add 1 point
② transmission output
③ external power supply (24V or 12V)
④ Communication Interface: RS 232 or RS 485
| content | Code Description | |||||||||||
| XSC5 / | PID smart regulation, dual display, control output | |||||||||||
| shape size | A― | 160 (W) * 80 (H) * 125 (L) or 80 (W) * 160 (H) * 125 (L) | ||||||||||
| B― | 96 (W) * 96 (H) * 112 (L) | |||||||||||
| C― | 96 (W) * 48 (H) * 112 (L) or 48 (W) * 96 (H) * 112 (L) | |||||||||||
| D- | 72 (W) * 72 (H) * 112 (L) (limit XSC5) | |||||||||||
| E― | 48 (W) * 48 (H) * 112 (L) (limit XSC5) | |||||||||||
| Panel form | H | Horizontal | ||||||||||
| S | Vertical | |||||||||||
| F | Square | |||||||||||
| Input signal (When the input signal ordering others) | E | Thermocouple K, S, R, B, N, E, J, T or radiation temperature meter | ||||||||||
| R | RTD Pt100, Cu100, Cu50, BA1, BA2, G53 or resistance | |||||||||||
| I | DC current (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA | |||||||||||
| V | DC voltage (0 ~ 5) V, (1 ~ 5) V | |||||||||||
| M | DC mV (ordering range) | |||||||||||
| W | Potentiometer 500Ω ~ 5000Ω | |||||||||||
| L | Remote pressure gauge | |||||||||||
| Number of alarm points | T• | T0: No alarm T1 ~ T3: 1 ~ 3-point alarm | ||||||||||
| Control Output | C0 | No output | ||||||||||
| C1 | Current output (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA | |||||||||||
| C2 | Voltage output (0 ~ 5) V, (1 ~ 5) V | |||||||||||
| C3 | Voltage output (0 ~ 10) V | |||||||||||
| C4 | Solid state relay drive output voltage | |||||||||||
| C5 | SCR non-contact normally open output | |||||||||||
| C6 | SCR zero trigger output | |||||||||||
| C7 | Relay contact switch output | |||||||||||
| Transmission output (Independent power supply, full isolation. 10 D / A, the error is less than ± 0.5%, or 12 D / A, the error is less than ± 0.2%) | A0 | No output | ||||||||||
| A1 | Current output (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA | |||||||||||
| A2 | Voltage output (0 ~ 5) V, (1 ~ 5) V | |||||||||||
| A3 | Voltage output (0 ~ 10) V | |||||||||||
| A4 | Other output | |||||||||||
| External power supply | B0 | No external power supply | ||||||||||
| B1 | External supply 24V DC | |||||||||||
| B2 | External supply 12V DC | |||||||||||
| B3 | Outside for precision voltage source | |||||||||||
| B4 | Outside for precision current source | |||||||||||
| B5 | other | |||||||||||
| Communication Interface (Independent power supply, full isolation, 2400 ~ 19.2K instrument addresses 0 to 99, the response delay is less than 500μs) | S0 | No communication interface | ||||||||||
| S1 | RS-232 Interface | |||||||||||
| S2 | RS-485 Interface | |||||||||||
| Instrument Power | V0 | 220V AC | ||||||||||
| V1 | 24V DC | |||||||||||
| V2 | 12V DC | |||||||||||
| V3 | other | |||||||||||