ZRN-WRB series Integrated Temperature Transmitter By the temperature probe, temperature conversion module, the protective housing of three parts. Temperature probe PT1000 platinum resistance using a high-impedance type, filtering through the regulator internal conversion module, operational amplifier, nonlinear correction, V / I converter, constant current and After reverse power protection circuit such as processing, is converted into a linear relationship with the temperature of the electrical output, the products are widely used in process temperature petrochemical, power, metallurgy, medicine, food and other industrial areas of control with the composition of the instrument or PLC Distributed Computer Control system.
| model | Technical Parameters |
| ZRN-WRB | 1. Platinum Resistance: Pt1000 2. Temperature range: (-50 ~ 400) ℃ 3. Common Accuracy: 0.5%, 0.2%, 0.1% 4. Output: 4 ~ 20mA, 0 ~ 5V, etc. 5. atmospheric pressure, there is no pressure for the conditions, please indicate |
| model | Physical map | Schematic | Thread and flange specifications |
| A | No connection ![]() | ![]() | |
| B | Threaded connections, no cold end ![]() | ![]() | Common Thread Size: M• 16=M16*1.5 20=M20*1.5 22=M22*1.5 27 = M27 * 2 specified Standard Products: C = L + 150 1. Screw the top tight 2. The locking sleeve |
| C | Threaded connections, cold end ![]() | ||
| D | Threaded sleeve connection ![]() | ![]() | |
| E | Events flange connection ![]() | | Flange diameter (mm) ¢70 Apply pressure |
| F | Flange connection ![]() | ![]() | Flange diameter (mm) ¢95, ¢105 ¢ 115 three sizes Apply pressure |
| selected type table | |||||||||
| ZRN-WRB | | Platinum thermal resistance model | |||||||
| | T• | 1 = 2 = -50 to 100 -50 to 200 -50 to 250 designated 3 = | Temperature range (℃) | ||||||
| | P• | 5=0.5% 2=0.2% 1=0.1% | Sensor accuracy | ||||||
| | O• | A = 4 ~ 20mA B = 0 ~ 5V designated | output signal | ||||||
| | C• | 100=100 150=150 350=350 550=550 600=600 Designation | The total length of the protective tube (mm) | ||||||
| D• | 4 = 48 = 812 = 12 16 = 16 designated | Protection tube diameter (mm) | |||||||
| S• | 1 = SUS321 4 = SUS304 6 = SUS316 specified | Material threaded portion | |||||||
| | N•• | A = No Connection B = threaded connections, no cold end C = threaded connection, cold end D = threaded sleeve connection E = connection flanges F = fixed flange connection Designation See thread and flange specification table | Process connection type | ||||||
| | G• | 1 = BOP formula 2 = waterproof specify | Junction Box Type | ||||||
| | Z• | 0 = no, do not fill 2 = Armour type 3 = embalmed Designation | special request | ||||||
| Remark : For user-specified parameters required, directly to the number or text can be marked out. Selection example : ZRN-WRB -T2- P5- OA- C350 / D8 / S4 -NCM16 - G2 Explanation : Temperature range -50 ~ 200 ℃, accuracy 0.5%, protection tube diameter 8mm, output 4-20mA, protection tube total length 350mm. Thread size M16 * 1.5 junction box is waterproof formula | |||||||||
| • Feature Output 4-20mA, 1-5V anti-jamming; Saving temperature transmitter compensation wire and installation costs; Safe, reliable, long life; Automatic cold junction temperature compensation, nonlinear correction circuit; | |||||||||||
| | • working principle | ||||||||||
| TC (resistance) in working condition measured thermoelectric power (resistance) changes. After the bridge temperature transmitter unbalanced signal after amplification converted into 4-20 mA electrical signal to the working instruments, working instrument will show the corresponding temperature value. Proof thermocouple (resistance) the use of space explosion principle, when the cavity explosion. Flame through the gap and cooling joints, so after the explosion of flame and temperature not pass cavity In addition, in order to carry out temperature thermocouple (resistance) produced by thermoelectric power (resistance value) through Bridge temperature transmitter unbalanced signal after amplification converted into a 4-20mA DC signal to the workers instruments, working instrument shows the corresponding temperature value.
| |||||||||||
| | • The main technical parameters | ||||||||||
| | Product performance standards IEC584 IEC751 IEC1515 JB / T5518-91 JB / T7391-94 | ||||||||||
| | • Measuring range and tolerance | ||||||||||
| 1) Thermal resistance temperature measurement range and tolerance | |||||||||||
| | | ||||||||||
| | 2) thermocouple range and tolerance |