| A Product description: ZRN701B series HIP Level Transmitter Is based on the hydrostatic liquid height measured proportional principle, piezoresistive effect using foreign advanced isolated diffused silicon sensing element, the static pressure is converted to an electrical signal, and then after temperature compensation and linearity correction, converted to Standard electrical signal (usually 4 ~ 20mA), this input level meter hydrostatic Common type and field-type liquid crystal display two. ZRN701B series HIP Level Transmitter Used in petrochemical, metallurgical, power, pharmaceuticals, water supply and drainage, environmental protection systems, and liquid level measurement in various media industries. Compact structure, easy set-up and installation flexibility for users to easily use more convenient. 4 ~ 20mA, 0 ~ 5v, 0 ~ 10mA standard signal output, etc., optionally by the user as needed. Technical Parameters: | Measurement form and scope | 0 ~ 1 ~ 200mH2O | | Allow overload | 2 times full scale pressure | | Operating temperature | -20~80℃ | | Temperature compensation | -10~70℃ | | storage temperature | -40~80℃ | | Accuracy (including non-linearity, repeatability, hysteresis) | 0.2% FS (typical) 0.5% FS (max.) | | Stability of the error | 0.2% FS (typical), 0.5% FS (max.) | | Drift coefficient | 0.01% FS (typical range of not less than 5mH2O) 0.03% FS (typical range of less than 5mH2O) | | output signal | (4 ~ 20) mA (two / three-wire), (0 ~ 10/20) mA (0 ~ 5) V, (1 ~ 5) V,) 0 ~ 10) V | | Power supply | 15 ~ 36 VDC (calibration voltage 24VDC) | | Load (Ω) | Current output type ((U-15V) /0.02A, current output type) 5K | | Housing Material | Aluminum alloy | | O-ring | fluororubber | | Diaphragm | 316L stainless steel | | cable | Waterproof breathable cable | | Protection class | IP68 (pressure sensor portion), IP65 (junction box transmitter section) | Product Selection: | ZRN701A- mouth E Port A Port C Port D port input type level transmitter | | | Input type level transmitter (specify range) | | | mouth | structure type | | | 1, integrated with no junction box (default) 2, split with Junction Box | | E port | output signal | | | 1, (0 ~ 5) VDC 2, two-wire (4 ~ 20) mA (default) 3, (0 ~ 10) mA 4, other specified | | A port | Accuracy | | | 10.1 20.2 30.5 | | C port | Probe Type | | | 1, the default is a standard (non-corrosion type) 2, anti-corrosion | | D port | Display mode (only with terminal box type Split) | | | 1. No display (default) 20 to 100% linear directions 3, LCD digital range display (LCD) 4, LCD display a number from 0 to 100% (liquid crystal) 5, digital display with HART protocol intelligent input level meter | | Third, the technical parameters: ☞ Range: 0 to within 100m of each range, the minimum range 0.5m ☞ Medium temperature: -20 ~ + 70 ℃ ☞ Ambient temperature: -10 ~ + 60 ℃ ☞ Supply voltage: 12 ~ 32VDC (usually 24VDC) ☞ Output signal: 0 ~ 10mA / 4 ~ 20mA / 0 ~ 5VDC / 1 ~ 5VDC ☞ Load characteristics: Current output type ≤600Ω Voltage output ≥3KΩ ☞ Insulation resistance:) 100 MΩ ☞ Accuracy: A grade: ± 0.25% FS Grade B: ± 0.5% FS ☞ Non-linear: (± 0.2% FS ☞ Hysteresis and repeatability: ≤ ± 0.1% FS ☞ Long-term stability: ≤ ± 0.1% FS / Year ☞ Thermal Zero drift: ≤ ± 0.03% FS / ℃ ☞ Response time: ≤100mS ☞ Maximum operating pressure: 2 times the range ☞ Electrical connection: cable ☞ External parts of the material: ordinary stainless steel / 316 stainless steel ☞ Housing material: ordinary stainless steel / 316 stainless steel / cast aluminum housing ☞ Measuring media: oil, water, gas and other media compatible with 316 stainless steel ☞ Protection class: IP 68 ☞ Intrinsically safe: ExiaIICT6 Four applications: Widely used in water plants, sewage treatment plants, urban water supply, high-rise pools, wells, mines, industrial pools, pour the oil tank, oil filling, hydrogeology, reservoirs, rivers, oceans and other places.
|