bargain
add to cart
Explanation:
① 2~ 4 measurement channels, independent display. Addition, subtraction, average, multiplication, and division operations function and maximum, minimum determination function
② basic error is better than ± 0.2% F · S. 16 bit A / D converter for measuring speed of 0.2 seconds / per channel
③ anti-jamming design, inhibit the rapid burst interference relays, contactors, etc. produced by the scene and other electromagnetic interference, immunity to level III
④ Input signals include: thermal resistance, thermocouple, DC current, DC voltage
⑤ Dimensions: 160 * 80 (horizontal / vertical)
⑥ instrument power 220V AC. (9~ 30) V DC
basic configuration
2-channel input, dual display
extensions
① increase a measurement channels and display
② Alarm output: up to 4:00
③ Transmitting output: up to two (isolation)
④ outside for the general power supply: 24V or 12V, current is greater than 60mA
⑤ Communication Interface: RS 485 or RS 232
⑥ printer interface (without the printer unit)
Selection Tables
| content | Code Description | |||||||||||||||||
| XSD / | 2-channel input, dual display | |||||||||||||||||
| Dimensions | A― | 160 * 80 * 105 or 80 * 160 * 105 (W * H * L) | ||||||||||||||||
| Panel form (Display color can be ordered on request) | H | Horizontal all-digital display (red) | ||||||||||||||||
| S | Vertical all-digital display (red) | |||||||||||||||||
| G | Vertical double digit + double-column display (limited to 2-channel instruments), a green channel, 2 channel red | |||||||||||||||||
| Number of Channels | 2 | 2-channel instrument | ||||||||||||||||
| 3 | 3-channel instrument | |||||||||||||||||
| 4 | 4-channel instrument | |||||||||||||||||
| 1234 order of an input signal channels (other input signal, when ordering) | E | E | E | E | Thermocouple K, S, R, B, N, E, J, T or radiation temperature meter | |||||||||||||
| R | R | R | R | RTD Pt100, Cu100, Cu50, BA1, BA2, G53 or resistance | ||||||||||||||
| I | I | I | I | DC current (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA | ||||||||||||||
| V | V | V | V | DC voltage (0 ~ 5) V, (1 ~ 5) V | ||||||||||||||
| M | M | M | M | mV signal (ordering range) | ||||||||||||||
| W | W | W | W | Potentiometer | ||||||||||||||
| L | L | L | L | Remote pressure gauge | ||||||||||||||
| Number of alarm points | T• | T0: No alarm T1 ~ T4: 1 ~ 4 point alarm | ||||||||||||||||
| Transmission output (independent power supply, full isolation. 12 D / A, the error is less than ± 0.2%) | A0 | No output | ||||||||||||||||
| A1 | Single Output | |||||||||||||||||
| A2 | Dual Output | |||||||||||||||||
| External power supply | B0 | No external power supply | ||||||||||||||||
| B1 | External supply 24V DC, error is less than ± 5%, greater than 60mA | |||||||||||||||||
| B2 | External supply 12V DC, error is less than ± 5%, greater than 60mA | |||||||||||||||||
| B3 | Outside for precision voltage source | |||||||||||||||||
| B4 | Outside for precision current source | |||||||||||||||||
| B5 | Other (ordering please specify) | |||||||||||||||||
| Communication Interface (Independent power supply, full isolation, 1200 ~ 19.2K instrument addresses 0 to 99, the response delay is less than 500μs) | S0 | No communication interface | ||||||||||||||||
| S1 | RS-232 Interface | |||||||||||||||||
| S2 | RS-485 Interface | |||||||||||||||||
| Instrument Power | V0 | 220V AC | ||||||||||||||||
| V1 | 24V DC | |||||||||||||||||
| V2 | 12V DC | |||||||||||||||||
| V3 | Other (ordering please specify) | |||||||||||||||||
| Print function (limited to A-type instrument) (with hardware clock) | P | P represents print interface | ||||||||||||||||