250KVA Cummins Generator
Features | Benefits |
Powered by the world-famous engine – Cummins engine | Function stability credibility, service convenience |
Tightly structure, excellent design and craft | Beautiful appearance |
High durability at maximum performance | Low life cycle operating cost results in optimal economy |
Excellent cooling system, reliable operation under harshest conditions (ambient temperatures up to 40°C and altitudes up to 1000 m) | Gets the job done wherever you are |
Key start or auto start (by LCD) type of modules | Allows complete control; easy connecting; ease of operation |
A full set of manuals: Install manual; Operation manual; the spare parts manual and electric circuit | Ease of installation; operation; and maintenance |
Optional sound attenuated enclosures available | |
Designed with safety in mind Earth leakage protectionQuick fix electrical power connections | Safety first |
Extensive option list. | Customization |
A Full load test is conducted at 25%; 50%; 75%; 100% and 110% | Good quality ensure |
Specification:
Standby Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275kVA/ 220kW
Prime Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250kVA/ 200kW
Dry weigh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2904.2kg
Noise level @7m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70.5dBA
Dimensions L*W*H. . . . . . . . . . . . . . . . . . . . . . . . . 3592*1300*2028.7mm
Engine Manufacturer/ Brand...................................Cummins
Engine Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6LTAA8.9G2
Dimensions L*W*H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/ A
Dry Weigh (approx.) ...................................................650kg
Number of Cylinders. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Bore.......................................................................... 114mm
Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145mm
Displacement................................................................. 8.9L
Compression Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/ A
Type of injection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct injection
Intake System. . . . . . . . . Turbocharged, air-to-air charge cooled
Intake Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2kPa
Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water cooled
Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pusher
Battery Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12/24V
Type of Fuel................................................................Diesel
Type of Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . ACEA E2, API CF, CF-4, CG-4
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27.6L
Type of Coolant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glycol mixture
Coolant Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.3L
Back Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1kPa
Standby Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240kW
Continuous Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220kW
Fuel Consumption (100%load) .............................197g/ kW.h
Alternator Manufacturer/ Brand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stamford
Alternator Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UCDI274K
Exciter................................................................... Brushless
Cooling Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cast alloy aluminum
Windings.......................................................... 100% copper
Insulation Class .................................................................H
Winding Pitch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2/3
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Drip Proof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP23
Altitude..................................................................... ≤1000m
Overspeed.............................................................. 2250rpm
Air Flow. . . . . . . . . . . . . . . . . . . . . . . . . . 0.514m³/ s (50Hz) ,0.617m³/ s (60Hz)
Voltage Regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1.0%
Total harmonic TGH / THCat no load ( 1.5 % - on load ( 5%
Telephone Interference..............................THF (2%; TIF (50
Control System:
Microprocessor control, with high stability and credibility .
Mains supply and generator operation monitoring.
Indicating operation status and fault conditions.
Multiple protections; multiple parameters display, such as
pressure, temperature.
Manual and automatic work mode selectable.
Real time clock for time and date display, overall runtime
display, 99 log entries.
Overall power output display.
Integral speed/ frequency detecting; telling status of start; rated
operation, overspeed.
Communication with PC via RS485 or RS232 interface, using
MODBUS protocol.
Engine ECU is available.
Common USB cable is usable for parameter configuration.
Multi-language is available. It can be translated for only one
time and imported in forever. The idiom can also be changed
after translation, eg. Failure to be Malfunction