| Brand: Nine Year | Type: AC / DC power supply | Modulation: Pulse width modulation (PWM) Formula |
| Transistor connection: Full-bridge | Input voltage: 170 ~ 264VAC (V) | Output power: 120 (W) |
| Output voltage: 12 (V) | Efficiency: 82 (%) | Output ripple and noise: 100mVp-p |
| Output voltage accuracy: ± 1 (%) | Voltage Regulation: ± 10 (%) | Load Regulation: ± 1 (%) |
| Product Certification: CE | Model: LPV-120-12 |
This product features:
• Small size; light weight; high efficiency
• constant voltage mode power supplies
• Small size; light weight; high efficiency
• Protection Features: Short circuit / overload / overtemperature / overvoltage
• 100% full load burn-in test
• Waterproof to IP67
specification:
• Size 222 * 69 * 43
• enter
Voltage range: 170 ~ 264VAC 47 ~ 63Hz, 235 ~ 373vDC
AC input current: 1.5 A / 230VAC
The impact of current: Cold start current 40A / 230VAC
Leakage current: (2.5mA / 240VAC
• Output
DC output voltage: 12 V
Rated output current: 10A
Output Power: 120W
Output voltage tolerance: ± 1%
Start; rise; hold time: 800ms; 30ms; 24ms / 230VAC
• Efficiency 82%
• protection
Overload protection: 105% ~ 135% of rated output power start overload protection
Protection: After the hiccup mode, load exception conditions removed automatic recovery
Overtemperature protection: Case temperature ≥85 ℃ start over-temperature protection
Protection mode: Shutdown output, when the temperature returns to normal automatic recovery
Overvoltage protection: 15.8-18.8 V
Protection: After the hiccup protection, load exception conditions removed automatic recovery
Operating temperature and humidity: -10 ℃ ~ + 60 ℃; 20% ~ 90% RH (Refer to Derating Curve)
Storage temperature and humidity: -20 ℃ ~ + 85 ℃; 10% ~ 95% RH non-condensing
Shock resistance:. 10 ~ 500Hz, 2G 10min / 1 cycle, duration 60 minutes, each axis
Insulation resistance: between input and output: 100M Ohms / 500VDC
Safety standards, protection class: Conforms to UL1012 IP67
EMC standards: EN55022, CLASS 2
Note: 1. All parameters NOT specially mentioned are measured values obtained at 230VAC input, rated load and 25 ℃.
2. Ripple and noise voltage in 20MHz of bandwidth by 12 inches twisted pair end with overtime 0.1μ and 47μ capacitor measured.
3. Tolerance is the sum of the voltage setting error, voltage regulation and load regulation.
• Packing: Neutral white box
• Single product weight: 1.2 Kg 20 Pcs / Box