bargain
add to cartThree-phase power supply protection, phase-sequence protection GMR-32B the spot
Main products:
Mitsubishi's full range of products, Panasonic servo, Profis.
Haitaike; Yaskawa; Siemens; Timeout
Shanghai plastic automation systems, Ltd
Address: Pu building, lane 95, Fengxian district, Shanghai
People: Lee/15901631703
Phone: 021-60640260
Contact QQ:291577518
Three-phase power phase-sequence protection for GMR-52B1F
Protector for three-phase power GMR-YK-32B
Protector for three-phase power supply GMR-32B GMPR-ZT
Protector for three-phase power supply GMR-32B1 GMPR-IT
Protector for three-phase power supply GMR-32B3 GMPR-AT
Protector for three-phase power supply GMR-52B GMR-32
Protector for three-phase power supply GMR-32BD GMPR-ZS
Protector for three-phase power supply GMR-32BT GMPR-IS
Protector for three-phase power supply GMR-32BH GMPR-NT
Protector for three-phase power supply GMR-32BL GMPR-NS
Protector for three-phase power supply GMR-22A GMPR-AS
GMR series multifunctional power protector (also known as three
Phase power monitor; Phase sequence protectors; Over/under voltage protection
And so on) is mainly used for Exchange 50/60Hz, rated voltage
460V, industrial three-phase 220V, 380V, 440V.
460V fault detection for various voltage levels, three-phase
High input power voltage, low voltage, phase.
Phase (phase), and provided unbalanced three-phase voltage relay
Protection products are widely used in air compressors, electric motors.
Distribution box Water pump; Oil pump; Central air conditioning units; Electricity
Control box; Distribution Cabinet Cranes, etc; Such as central air conditioning pressure
Compressor protection, Elevator power monitoring, water pump.
Oil well pump phase; Reverse phase protection; Industrial equipment
Line maintenance equipment indispensable to the normal working voltage
Protection products.
Three-phase power supply protection, phase-sequence protection
ABJ1-14WBX ABJ1-14FP ABJ1-12W
ABJ1-14W ABJ1-19AH ABJ1-18AY
ABJ1-18DY ABJ1-14FY ABJ1-122
ABJ1-14WFX ABJ1-14WAX ABJ1-10W
ABJ1-12 ABJ1-14FY ABJ1-14CY
ABJ1-18AH
ABJ1 series introduction protection of three-phase AC relay
Is the company for development and production of miniature products. According to
With models protection features are: over-voltage protection. Under voltage
Protect. Phase sequence protection. Dynamic phase-failure protection. Static phase
Nurse. voltage unbalance protection. X-type delay protection
(Not more than 3 seconds delay time) the protective relay design
Principle of novelty. Reliable and strong resistance to voltage fluctuations,
Line easy installation and reliable, clear failure display. Production type
Number: ABJ1-10W; ABJ1-12w; ABJ1-14w
Following is the
(ABJ1-10W; ABJ1-12W; ABJ1-14WFX
ABJ1-14WBX; ABJ1-14FY; ABJ1-18DY
ABJ1-18AY; ABJ1-19AH; ABJ1-122)
Product ~~
-10W
ABJ1-10W is our independent research and development of three-phase AC
Micro protection relay product features: stagger protection jobs
Power supply rated voltage: 380VAC response time: 1S amount
Working voltage: 240VAC, 24VDC operating current
: 1A (AC-14, DC-13)
-12W
ABJ1-12W is our independent research and development of three-phase AC
Micro protection relay product features: fault phase protection,
State phase; Static phase; Voltage unbalance in power supply
Rated voltage: 380VAC voltage unbalance rate setting: 8%
Response time: 2S rated working voltage:
240VAC, 24VDC operating current: 1 a (AC-
14, DC-13)
-14WFX
ABJ1-14WFX is our independent research and development of three-phase AC
Current protection relay mini product features: dynamic phase.
Static phase, voltage unbalance, phase dislocation, overvoltage.
Under voltage protection operating power rated voltage: 380VAC
Set the voltage unbalance rate: 8% voltage: 428VAC
Under voltage: 332VAC response time: 3S
Voltage: 240VAC, 24VDC operating current: 1A
(AC-14, DC-13)
-14WBX
ABJ1-14WBX is our independent research and development of three-phase AC
Current protection relay mini
Product features: dynamic phase; Static phase; Voltage does not
Balance; Wrong phase; Over voltage; Under voltage protection; Occupation
Power supply rated voltage: 380VAC set the voltage unbalance rate
: 8% voltage: 437VAC under voltage: 323VAC
Protecting delay: 3S rated working voltage: 240VAC, 24VDC
Rated working current: 1 a (AC-14, DC-13)
-14FY
ABJ1-14FY is our factory developed the production load
Protection protection of three-phase AC relay a; B; C
Dynamic phase, stationary phase, voltage imbalance.
Wrong, over voltage, under voltage protection. Power supply rated power
Voltage: 380VAC voltage unbalance rate setting: 8%
The protection setting: set 428VAC under-voltage protection: 332VAC
Response time: 5S recovery delay: 5Min contact date
: 2C rated voltage (contacts):
240VAC, 24VDC operating current (contacts):
1A (AC-14, DC-13)
-18DY
ABJ1-18DY is our factory developed the production load
Nurse-adjustable three-phase AC relay products.
The model has two sets of unbalanced phase and voltage monitoring sensor
Monitoring of contacts of AC contactors. This monitoring
Is a unique invention patented product of our company.
ABJ1-18DY models have been applied to the Dalian refrigeration shares
Limited and the Wuhan McQuay air conditioning and refrigeration co
Compressor protection control system, such as the Secretary for more than five years, without undue
With disabilities; With good reliability; Monitoring comprehensive and many other
Advantages. A, b, c features: dynamic phase, static broken
Phase; Voltage unbalance; Wrong phase; Over voltage; Under voltage protection
. a; b; C features: dynamic phase, stationary phase.
Voltage unbalance protection. Power supply rated voltage:
380VAC voltage unbalance rate setting: 8% overvoltage protection
Set up: set 420VAC under-voltage protection: 340VAC
Time: 5S recovery delay: 5Min
Pressure (contact): 240VAC, 24VDC operating current
(Contacts): 1 a (AC-14, DC-13)
-18AH
ABJ1-18AY is our factory developed the production load
Protection protection of three-phase AC relay a; B; C
Dynamic phase, stationary phase, voltage imbalance.
Wrong, over voltage, under voltage protection. A, b, and c functions:
Dynamic phase, stationary phase, voltage unbalance protection.
Rated voltage: 380VAC working voltage: 380VAC
Set the voltage unbalance rate of 20%: 8% overvoltage protection setting
420VAC under-voltage protection setting: 340VAC protection delay
Time: 5S phase-failure protection delay: 1S recovery delay:
5Min rated voltage (contacts):
240VAC, 24VDC operating current (contacts):
1A (AC-14, DC-13)
-19AH
ABJ1-19AH three-phase AC detector is our self-study
Production and protection of three-phase AC with load monitoring and protection
Relay a; B; C features: dynamic phase, static
State phase; Voltage unbalance; Wrong phase; Over voltage; Undervoltage
Monitoring. A, b, c features: dynamic phase, static broken
Phase unbalance voltage monitoring. Ambient temperature:-
25oC~+55oC relative humidity: (90% rated voltage:
380VAC ± 20% 50~60HZ set the voltage unbalance rate
: (8% overvoltage protection setting: 420VAC under-voltage protection set
Fixed: 340VAC protection delay: 5S 20% recovery delay
5Min ± 20% rated voltage (contacts):
250VAC, 28VDC nominal current (contacts):
1A (AC-14, DC-13)
-122
ABJ1-122 is our factory developed the production load protection
The protection of three-phase AC relay a; B; C function
Dynamic phase; Static phase; Voltage unbalance; Wrong
Protection power supply rated voltage: 380VAC voltage
Balance rate setting: 8% response time: 2S contact date
: 2C rated voltage (contacts):
240VAC, 24VDC operating current (contacts):
1A (AC-14, DC-13)
This product meets the GB14085.5-2001 Eqv
IEC60947-1:1999 standards.
Warning! this product is usually on three-phase power supply power supply side
The sampling shall be installed at the output side of variable frequency current!
Structure characteristic
1) installation: the protector base using guide rail.
Equipped with two M4 screw hole structure, direct the standalone installation or the
HT35 rail installation.
2) led: 5 LEDs to indicate respectively:
Normal phase (voltage for three-phase unbalance), reverse phase.
Overvoltage, undervoltage.
3) dimensions: 68mm*30mm*76mm.
Second, protection
1) lack of protection: the protected circuit is in operation, or
When not running, any one phase open-phase fault occurs.
Delay 2S action.
2) reverse phase protection: prevent L1; L2; L3 phase-three-phase AC
Sequence on the wrong kind of protection measures, delay 2S action.
3) voltage unbalance protection: unbalanced three-phase voltage
Will affect the line safe operation of a protective measure, the three
Unbalanced phase rate = *100%) 10%, protection delay 2S
Action.
4) over voltage protection: the voltage of the protected circuit is higher than the set
Value of delayed 3~8S, recovered back to the poor as 6~20VAC.
5) undervoltage protection: refers to the voltage of the protected circuit is lower than the set
Value of delayed 3~8S, recovered back to the poor as 3~20VAC.
Three main technical data
1) main circuit:
Rated voltage: 220VAC and 380VAC, 440VAC.
460VAC.
2) main circuit connection wire: insulated copper wire the load area
1.0~2.5mm. Single strand copper wire directly into the Terminal
If using cord, you must add in the wire-pin type
Lint, to ensure a reliable connection.
2 auxiliary circuit:
1) electrical indivisible one normally open and one normally closed contact
2) use category: AC15, DC13
3) contact capacity 250VAC 2.5A, 30VDC 1.5A
4) conventional thermal current: 5A
CE certification
Our ABJ1-12W and ABJ1-14W models
Product has advanced technology and price advantage, in 2003 to country
Market and marketing in the European Union, the Middle East and Southeast Asia.
System certification
ABJ1 series and ABJ1-W series are produced by our company
National Center for quality management system certification