bargain
add to cart All three-phase procurement timeout data products available from stock
Three-phase power protection, phase sequence protection GMR-32B Spot
Three-phase power supply phase sequence protection GMR-52B1F
Three-phase power protection
GMR Series multifunction power protection device (also known as three-phase power
Source monitor; phase sequence protection; over voltage protection, etc.)
Primarily for the exchange of 50 / 60Hz, rated voltage of 460V or less.
Industrial three-phase 220V; 380V; 440V; 460V and other voltage levels
Other various fault detection, three-phase power supply input voltage
Too high; voltage is too low; phase; inverse phase (phase sequence), phase
Voltage unbalance to provide protection, products widely used
In air compressors, motors, power distribution box, water pump, oil pump.
Central air conditioning units; electronic control box; distribution cabinet; cranes, etc.
, Such as central air conditioning compressor protection, various elevator power
Surveillance; pump; pump anti-phase; reverse phase protection; is
Industrial equipment operating in the normal operating voltage maintenance equipment not
Indispensable protection products.
GMR-32 GMR-32B GMR-32B1
GMR-32B3 GMR-32BD GMR-32BL
GMR-32BH GMR-32BT GMR-YK-32B
GMR-52B GMR-22A
GMPR-ZT GMPR-IT GMPR-AT
GMPR-ZS GMPR-IS GMPR-AS
GMPR-NT GMPR-NS
Main business:
Mitsubishi full range of products; Panasonic servo; general Griffith; sea
Tektronix; Yasukawa; Siemens; timeout
Shanghai Kun Plastic Automation System Co., Ltd.
Address: Fengxian District, Building 95, Lane Fengpu
Contact: Mr. Li / 15901631703
Tel: 021-60640260
Contact QQ: 291577518
Fax: 021-61240084
Three-phase power protection, phase sequence protection
ABJ1-10W ABJ1-12W ABJ1-14WFX
ABJ1-14WBX ABJ1-14FY ABJ1-18DY
ABJ1-18AY ABJ1-19AH ABJ1-122
ABJ1-14CY ABJ1-12 ABJ1-18AH
ABJ1-14W ABJ1-14FP ABJ1-14WAX
About ABJ1 series three-phase AC protection relay
Is the company's development and production of micro-products. Depending on the
Model protection functions: Overvoltage protection undervoltage protection.
Phase sequence protection dynamic phase protection static phase protection. Voltage
Unbalance protection .X type have delay protection (Delay time
Not more than 3 seconds) Novel design principle of the protection relay. Of
Reliable; strong ability of anti-voltage fluctuation; wiring installation easily available
By, fault display clarity.
The following is a (ABJ1-10W; ABJ1-12W; ABJ1
-14WFX ABJ1-14WBX; ABJ1-14FY; ABJ1-18DY
ABJ1-18AY; ABJ1-19AH; ABJ1-122)
Product ~~
• ═━10W
ABJ1-10W is my factory developed the production of three-phase AC protection
Micro product features protection relay: Wrong phase power protection
Rated voltage: 380VAC response time: 1S rated working
Voltage: 240VAC, 24VDC rated current: 1A (AC
-14, DC-13)
• ═━12W
ABJ1-12W is my factory developed the production of three-phase AC protection
Micro product features protection relay: Wrong phase protection, dynamic off
Phase; static phase; operating supply voltage unbalance rated
Pressure: 380VAC voltage unbalance rate setting: 8% Response time
Room: 2S rated working voltage: 240VAC, 24VDC rated
Working current: 1A (AC-14, DC-13)
• ═━14WFX
ABJ1-14WFX is my factory developed the production of three-phase AC
Micro product features protection relay: Dynamic off-phase, static
Off phase; voltage imbalance; wrong phase; overvoltage; undervoltage
Protection, working power rated voltage: 380VAC voltage uneven
Heng rate setting: 8% over voltage: 428VAC undervoltage:
332VAC response time: 3S rated working voltage:
240VAC, 24VDC rated current: 1A (AC-14, DC
-13)
• ═━14WBX
ABJ1-14WBX is my factory developed the production of three-phase AC
Protection Relays Miniature
Product Features: Dynamic off-phase; static phase; voltage uneven
Heng; wrong phase; overvoltage; under voltage protection; working power
Rated voltage: 380VAC voltage unbalance rate setting: 8%
Overvoltage: 437VAC undervoltage: 323VAC protection delay
: 3S rated working voltage: 240VAC, 24VDC rated workers
Operating current: 1A (AC-14, DC-13)
• ═━14FY
ABJ1-14FY is my factory developed the production with load protection
The three-phase protection relays A; B; C function:
Dynamic off-phase, static phase, voltage unbalance, phase error.
Overvoltage, undervoltage protection voltage rating:
380VAC voltage unbalance rate setting: 8% over setting
Setting: 428VAC voltage protection settings: 332VAC response
Room: 5S recovery delay: 5Min shock form: 2C rated
Operating voltage (contact): 240VAC, 24VDC rated working
Current (contact): 1A (AC-14, DC-13)
• ═━18DY
ABJ1-18DY is my factory developed the production with load protection
Adjustable three-phase AC protection relay products. This type of
No. There are two sets of voltage unbalance and phase failure monitoring sensors for AC
Flow contactor is monitored. This monitoring mode is I
The company's unique patent products. ABJ1-18DY Model
It has been used in Dalian Refrigeration Co., Ltd. and Wuhan
McQuay Air Conditioning and Refrigeration Co., Ltd., compressor protection control
Prepared system over five years; no failure; with reliability
Good, comprehensive monitoring and many other advantages A, B, C function:
Dynamic off-phase, static phase, voltage unbalance, phase error.
. Overvoltage, undervoltage protection a, b, c function: Dynamic off-phase
, Static phase, voltage unbalance protection Power supply amount
Constant voltage: 380VAC voltage unbalance rate setting: 8% over
Voltage protection setting: 420VAC voltage protection settings: 340VAC
Response time: 5S recovery delay: 5Min rated operating voltage
Pressure (contact): 240VAC, 24VDC rated current (
Contacts): 1A (AC-14, DC-13)
• ═━18AH
ABJ1-18AY is my factory developed the production with load protection
The three-phase protection relays A; B; C function:
Dynamic off-phase, static phase, voltage unbalance, phase error.
. Overvoltage, undervoltage protection a, b, c function: Dynamic off-phase
, Static phase, voltage unbalance protection rated voltage:
380VAC working voltage: 380VAC ± 20% voltage imbalance
Rate setting: 8% over setting: 420VAC undervoltage protection
Protection setting: 340VAC protection delay: 5S-phase protection delay
When: 1S recovery delay: 5Min rated working voltage (touch
Point): 240VAC, 24VDC rated current (contact)
: 1A (AC-14, DC-13)
• ═━19AH
ABJ1-19AH phase AC detector is my own research and development plant
Producing a three-phase AC load protection monitoring and protection relay
Product A; B; C function: dynamic off-phase, static phase
Voltage unbalance, phase error, overvoltage, undervoltage monitoring. A
, B, c function: Dynamic off-phase; static phase; voltage is not
Monitoring of environmental equilibrium temperature:. -25oC ~ + 55oC relative humidity
Degree: (90% of rated voltage: 380VAC ± 20% 50 ~ 60HZ
Voltage unbalance rate setting: (8% over setting:
420VAC voltage protection settings: 340VAC protection delay:
5S ± 20% recovery delay: 5Min ± 20% of rated operating voltage
Pressure (contact): 250VAC, 28VDC rated current (
Contacts): 1A (AC-14, DC-13)
• ═━122
ABJ1-122 is my factory developed the production with load protection
Three-phase protection relays A; B; C function: Dynamic
State off-phase; static phase; voltage imbalance; wrong phase protection
Working power rated voltage: 380VAC voltage unbalance rate setting
Setting: 8% Response Time: 2S form of electric shock: 2C rated working
Operating voltage (contact): 240VAC, 24VDC nominal operating power
Flow (contact): 1A (AC-14, DC-13)
This product complies with GB14085.5-2001 eqv IEC60947
-1: 1999 standards.
Warning! This product generally is a three-phase power supply side of mining
Kind, shall not be installed on the output side of the inverter current!
First, the structural characteristics
1) Installation: The base is made of rail protectors, inside
Let two M4 screw structure, stand-alone installation or HT35 direct guide
Rail installation.
2) indicator: the five LEDs to indicate, respectively: n
Often, phase (voltage phase imbalance), reverse phase, overvoltage
Undervoltage.
3) Dimensions: 68mm * 30mm * 76mm.
Second, the protection features
1) Phase protection: Refers to the protection circuit in the running state or
When you run the state; any one phase open-phase fault occurs; delay
2S action.
2) Reverse phase protection: Prevent L1; L2; L3 phase AC phase sequence
A wrong connection protection, delay 2S action.
3) Voltage unbalance protection: Refers to the three-phase voltage imbalance will
A protective measures affecting the safe operation of the line, three-phase
Balance rate = * 100%) 10%, protection delay 2S action.
4) Overvoltage Protection: Refers to the protection circuit voltage is higher than the set value
Delay 3 ~ 8S action, recovery hysteresis is 6 ~ 20VAC.
5) Undervoltage protection: Refers to the protection circuit voltage is lower than the set value
Delay 3 ~ 8S action, recovery hysteresis is 3 ~ 20VAC.
Third, the main technical data
1) Main circuit:
Rated voltage: 220VAC, 380VAC, 440VAC.
460VAC.
2) Connect the wires of the main circuit: insulated copper wire which is contained area
. 1.0 ~ 2.5mm single strand copper wire can be inserted if the terminal directly;
The use of soft lines, you must add needle lugs on the wire
To ensure reliable connection.
2 auxiliary circuit:
1) has an electrical inseparable one normally open and one normally closed contact 2
) Utilization category: AC15, DC13
3) Contact capacity: 250VAC 2.5A, 30VDC 1.5A
4) Conventional thermal current: 5A
CE certification
I produced ABJ1-12W, ABJ1-14W models
A technologically advanced and price advantage, in 2003 on the international market
Field, marketing EU, Middle East and Southeast Asia.
System Certification
I produced ABJ1 series and ABJ1-W series have received
Quality Management System Certificate National Quality Center