bargain
add to cartDistributor: Model 820-type non-invasive kV line X- table mAs mAs meter
For more details, please visit: http: //www.huaruison.com
http: //www.xraytest.cn
Beijing Hua Ruisen Technology Development Co., Ltd. of China's total company sales of US ECC quality control instrument X-ray machine / X-ray machine performance testing equipment, there are: 870 mA / mAs mA stopwatch watch digital mAs table; Model 820 type non-intervention X- line kilovolt table; kVp kV mAs mA stopwatch and exposure table timetable; Model 890 X-ray diagnostic dosimeter; X-ray machine X-ray machine dose meter Gy / uGy meter
American Company Model 820 type ECC mAs kVp kV mAs and exposure schedule table features:
• Combine KVp kV and mA mAs means two in one
• Easy operation
• no need to set the AC / DC
• mAs mA stopwatch automatically reset
• mA mA applies to short-term exposure
• No diffuse
• AC or DC X-ray
• High accuracy
• measurable kilovolt peak; mA; mAs exposure time
• Battery powered
• Two-year warranty
• Custom suitcase
• Solid-state design data
• durable plastic box
Performance description
• as kVp kV mAs mA stopwatch or table use
• mA mA and mAs mAs measurement of X-ray tube current
• KVp kilovolt measure to accelerate the tungsten X-ray generator X-ray peak voltage
• direct measurement kilovolt peak from the X-ray head, simply 820 on the airwaves, according to X-rays.
• Press the Mode switch to display the exposure time
• Instruct X-ray wavelength format type -
For example: a half wavelength or full wavelength DC / 3 Phase
• Optimization of dental X-rays, also apply to the imaging and X-ray fluorescence
• a clear X-ray outdoor large-screen display
• alphanumeric display provides easy-to-understand status and error messages
• Insert cable mAs and mA per measuring milli An Peipei
• Unplug the cable mAs measurement kV peak
typical application
• Check voltage X-ray peaks
• Check approved sex
• Calibration X-ray
• Quality assurance
• measuring the exposure time
• Determination of the half-value layer
• troubleshooting and maintenance of X-ray
• Service quality X-rays
Technical Parameters
820 / 820L Measuring range:
820: 45-125 kV 0.1 mA -2 amps 820L: 40 到 115 kilovolt
Kilovolt peak accuracy
15 mm aluminum equivalent filtration comprising a tungsten target X-ray tube 25 to each
100 mA (820) or 10-50 mA (820L) 2 each
% + / - Of 1 kV
Precision exposure time
1% + / - 2 ms (1/5 to
2 seconds) the minimum exposure time is 100 milliseconds
Shortest exposure time
100 ms - high-speed mode
200 ms - High resolution mode
Minimum current (mA)
7 mA per 50 kilovolt (820) or 5 mA, depending on the focal length
Different
820 / 820L type mAs measurement range:
Full range 0.1 mA -2 amperes
0.1 mA decomposition (mA or mA per second)
10 ohm input resistance of full scale 2 Amps
1 mA decomposition (mA or mA per second)
1 ohm input resistance
Meter automatically selects the AC / DC
By push button switch range
MA accuracy per second
Were 2% + / within two ranges --1 mA
Connected via two alligator clips 1 meter long cable with
Basic features:
Display: 10.2 mm LCD, 8-character alphanumeric Processor
Instructions
• On / Off - Lighting green button Power -
Energized Display
• Mode Switch - Instant Button
• 8 character LCD display
Without connecting kilovolt peak measuring device
power supply
• bottom means 4AA batteries
• Prompt power shortage
Power usage time
• Continuous apply 48 hours
• Normally normal 9 months
Warranty period from two years from the time of delivery
Specific size 150 X 120 X 58.5 毫米
Quality 0.7 kg
Beijing Science and Technology Development Co., Ltd. Hua Ruisen
2nd Floor, Block 16, Building A perfect circle square and Guanghua Road Beijing Tongzhou District, Tongzhou Industrial Development Zone
Tel / Fax: 010-57118919 (straight line) 010-51266093 (switchboard) 18001279800
QQ: 1275041125
Postal Code: 101113
E-mail:. Huarui51266093 @ 163 com
http: //www.huaruison.com
http: //www.xraytest.cn