bargain
add to cartDistributor: ECC870mA / mAs mA stopwatch mAs table table figures
For more details, please visit: http: //www.huaruison.comhttp: //www.xraytest.cnhttp: //www.eccxray.com/ zhongkao.html
Beijing Hua Ruisen Technology Development Co., Ltd. of China's total company sales of US ECC quality control instrument X-ray machine / X-ray machine performance testing equipment, there are: 870 mA / mAs mA stopwatch watch digital mAs table; Model 820 type non-intervention X- line kilovolt table; kVp kV mAs mA stopwatch and exposure table timetable; Model 890 X-ray diagnostic dosimeter (X-ray machine X-ray machine dose meter Gy / uGy meter)
feature
US ECC 870 mA / mAs mA stopwatch mAs table table digital compact portable, easy to operate
any type of measuring current X-ray
Single-phase full-wave multiphase DC
new high-standard circuit
automatic reset
built-in 9-volt battery
suitable for medical or dental X-rays
for digital X-ray
each reading display mA mA, mA mA per second / s and the exposure time
description
US ECC 870 mA / mAs mA stopwatch mAs meter digital meter for measuring the X-ray generator tube current
calculate the number of seconds of exposure time and milliamperes milliamperes
two leads connected in series via a tube current
calculate the exposure time in milliseconds
new and improved circuit to improve the accuracy and reliability
providing automatic detection of AC / DC
do not need to re-set
automatic storage and display mA, to minimize X-ray exposure of multiple
typical application
US ECC 870 mA / mAs mA stopwatch mAs digital table shows the exposure value milliampere per second to check by measuring X-ray tube filament emission
Check and adjust the mA settings
Check the X-ray exposure time
X-ray calibration timer
ensure quality
measuring the exposure time
analysis of X-ray fault
range
US ECC 870 mA / mAs table digital stopwatch mAs mA full-scale table is divided into 0.1 -200 mA and 200 mA -2 amperes two block (via the ON / OFF button to select the range)
-200 MA at 0.1 gear
accuracy of 0.1 mA (milliamps or mA per second)
10 ohm input impedance
Ampere at 200 mA -2 gear
accuracy of 1 milliamp (mA or mA per second)
1 ohm input impedance
instrument automatically selects AC / DC
through the ON / OFF button to select the range
MA / mA accuracy per second
full scale 1% + / - 2 mA
Connection: Jakes test head, test leads with two alligator clips
Display: 5.5mm LCD display, two lines of 16-character alphanumeric Processor
On / Off / Range Button
24 character LCD display
display each exposure milliamps, mA and exposure time readings per second
Power supply: 9 volt battery bottom configuration, the instrument automatically prompts power shortage
Power usage time: 100 hours of continuous use, under normal circumstances normal year
Size: 80 X 147 X 40 毫米
Weight 250 g
Beijing Science and Technology Development Co., Ltd. Hua Ruisen
2 seat on the 16th floor, Building A perfect circle square and Guanghua Road Beijing Tongzhou District, Tongzhou Industrial Development Zone
Tel / Fax: 010-57118919 (straight line) 010-51266093 (switchboard) 18001279800
QQ: 1275041125
Postal Code: 101113
E-mail:. Huarui51266093 @ 163 com
http: //www.huaruison.com
http: //www.xraytest.cn