bargain
add to cart
Sana couch
Beijing Hua Ruisen Technology Development Co., Ltd. China Regional Sales: Germany Sana couch
Hua Ruisen Technology Sana couch 150L Horizontal movement collapsed car can be used for normal horizontal horizontal / semi Horizontal security force.
Beijing Hua Ruisen Technology Sana couch 150L Horizontal movement collapsed car movement collapsed car in a special security, for example, after cardiac infarction or catheterization, cardiovascular disorders suspected pressure testing; there are other special exercise load applications, such as doing cardiovascular check, we need to use this dynamometer pressure reply dynamometer loungers are also recommended for the elderly and disabled patient examination.
Beijing Hua Ruisen Technology Sana couch 150L Horizontal movement collapsed car technical parameters of European safety standards: DIN 13405 and DIN VDE 0750-238 brake principle: eddy current brake device by measuring the torque generated by the computer-controlled, independent of revolutions per minute (i.e. speed-independent).
Load Range: 20-800 watts Speed range: 30-130 rev / min load accuracy: 3%, less than 3 watts of load setting: Set according to the load on the internal procedures; through the interface is set by an external host computer, a minimum accuracy of 1 W; manual settings can be performed at 5 watts -25 watts per grade.
Load Program: 5 sets of freely programmable dynamometer procedures; 1 set of automatic control pulse steady state program Interval: 1-99 minutes
Beijing Hua Ruisen Technology Sana couch 150L Horizontal movement collapsed car original blood pressure analysis parameters:
Pulse measurement: priority principle -1 ECG; 2. opto; 3. RR; measuring range 35-240 beats.
Blood pressure measurement: RR revision system uses a special indirect measurement; distortion during the measurement, the computer parsing and correction due to interference caused; to 3mmHg / pulse speed automatic release of pressure, rapid release of pressure at high amplitude equilibrium.
Loungers parameters: size 90 * 55cm, height adjustable from 140-205cm; maximum load 160kg through precise control, you can adjust the seat and pillows to the most suitable position of the patient is provided with a pillow under 50cm wide drum-shaped frame. . recliner position can be tilted from 45 ° (exercise position) to a flat position continuously adjustable tilt angle is adjusted by precise control of.
Riding help handle: On the left side of the head is equipped with an adjustable handle can be fixed, it can help patients up and down the deck chairs.
Germany Germany Sana couch 150L Horizontal movement collapsed car Options: Domestic ECG analysis system load
Domestic load ECG Analysis System Technical parameters:
The real synchronous 12-lead ECG test and measurement analysis
Real-time exercise ECG continuous recording, do not miss any second of ECG changes;
Full-lead ECG in real-time on-line analysis and storage.
Digital acquisition, RFA increment filtering technology / hardware module digital down dry / intelligent anti-zero drift system, high-quality, high-resolution ECG obtained;
Correspondence analysis sporty ST segment;
ST analysis and graphical real-time display and post-processing capabilities
Versatile multi-sport presets and custom exercise program
Report Optional / multi edit mode / database statistics
Powerful database statistical functions; network compatible.
It supports a variety of operating systems, automatic exercise ECG test abnormalities prompts alert
Extended Feature Support: exercise blood pressure, real-time thermal printer
Digital ECG signal acquisition system
Through a standard RS-232 / USB communication interface, isolation voltage up to 4000V between data communication and control complete with computers.
Using the latest 'isolation communication signal energy conversion' technology does not require any additional power supply or battery support, can complete a variety of ECG lead system amplification and analog to digital conversion.
Sampling rate per channel 1000S / s, sampling accuracy 14
Multiple digital filter makes clear and accurate recording results
Beijing Science and Technology Development Co., Ltd. Hua Ruisen
2 seat on the 16th floor, Building A perfect circle square and Guanghua Road Beijing Tongzhou District, Tongzhou Industrial Development Zone
Tel / Fax: 010-57118919 (straight line) 010-51266093 (switchboard) 18001279800
QQ: 1275041125
Postal Code: 101113
E-mail:. Huarui51266093 @ 163 com
http: //www.huaruison.com
Beijing Hua Ruisen Technology Nuclear Medicine Horizontal movement collapsed car activity meter http: //www.huaruison.com
Protective lead aprons and radiation detector http: //huaruisen.atobo.com.cn/
Radiation detection equipment and radiation protective equipment, radiation monitoring systems engineering http: //huaruisen.goepe.com/
Far infrared emission rate tester http:. //www.hi1718 Com / company / 239189 /
TL dosimeters, radiation detectors and radiation protection http: //www.huaruisen.cpooo.com/ product /
TL dosimeters, radiation detectors and radiation protection http: //www.szroom.com/ 1280681 /
Radiation safety and radiation protection http:. //www.cn5135 Com / ProductList-1-87605 html.
Nuclear Medicine Horizontal movement collapsed car activity meter http: //huaruisen.cn.nowec.com/ product.asp
Nuclear medicine instruments and environmental nuclear radiation instrument http:. //huaruisen.qy6 Com /
Radiometer activity meter movement collapsed car http: //www.caigou.com.cn/ c57946
Radiation detection equipment and Activity Meter http:. //www.chem17 Com / st126252 / Index.html
Radiation Safety and Radiation Protection http: //huaruisen.cn.china.cn/
Radiometer Activity Meter http: //www.hbzhan.com/ st20038
Contamination Monitor gamma dose rate meter activity meter http: //huaruisen.b2b.chemm.cn/
Activity Meter surface contamination measuring instrument http:. //www.labbase.net/ UserCompany / Default-6246 html
HPLC radioactivity detector radioactivity TLC scanner http:. //www.app17 Com / C16263 /