bargain
add to cart| Input voltage: 1 (V) | Waveform distortion: 1 (%) | Frequency regulation of: 1 (%) |
| Output voltage: 1 (V) | Load regulation: 1 (%) | Circuit mode: SPWM switching |
| Load Type: Mixed loads | Custom processing: | Efficiency: 1 (%) |
| Applications: appliance manufacturing | Type: AC Power Supply | Model: AF400 |
| Output frequency: 1 (Hz) | Brand: ACC | Product Certification: CCC |
| Control mode: Pulse width modulation type | Input Frequency: 1 (Hz) |
Features
Intelligent control, which enables remote communication;
Complete protection, safe and reliable operation;
Automatic memory function, remember last start when output condition;
Small size; light weight; low noise;
Strong overload capacity;
High reliability, good heat dissipation;
It provides reliable pure sine wave output, waveform distortion is better than 2%;
• Output response speed;
• Modular design, function relatively independent, extended combination of convenience and easy maintenance.
Implementation of standards
MH / T 6018-1999 ground static power
GJB 150-86 1 Environmental test methods for military equipments
GJB 151A-97 military equipment and subsystems electromagnetic emission and susceptibility requirements
GJB 152A-97 military equipment and subsystems electromagnetic emission and susceptibility measurements
MIL-STD-704E aircraft powered feature GJB 181A-2003 aircraft powered feature
GJB 572-88 aircraft ground power supply characteristics and general requirements
GJB 1440-92 definition of electrical and electronic equipment housing and basic requirements
GJB 3091-97 radar power distribution subsystem performance test method three-phase AC power supply
GJB 5189-2003 powered aircraft parameters Test Method
The main application areas
• aircraft production factories, aircraft overhaul facility;
• aerospace equipment manufacturing and repair shop;
• Air Force / Army / Navy radar detection system; troops ordnance repair shop; radar repairs;
• military airport apron, ground wells;
• ships, dock manufacturing and repair shop;
• defense and military research institutes, military academies;
• tower, turbine engine manufacturer.
Kyrgyzstan single-phase 400HZ IF static variable power supply technology parameters:
Specifications and performance indicators / single-phase output type Model
model | JL400-11001 | JL400-11005 | JL400-11010 | JL400-31015 | JL400-31030 | ||||
Output Capacity | 1KVA | 5KVA | 10KVA | 15KVA | 30KVA | ||||
AC input | Phase | Simplex | Phase four-wire | ||||||
Voltage | 220V ±15% | 380V+15% | |||||||
frequency | (50/60) Hz ± 5Hz | ||||||||
AC output | Phase | Simplex | |||||||
Voltage | Rated voltage: 115V; | ||||||||
frequency | Rated Frequency Output: 400Hz ± 0.4Hz | ||||||||
Total harmonic content | ≤2% | ||||||||
Single harmonic content | ≤1.5% | ||||||||
Display resolution | frequency | Four-digit display, resolution 0.1Hz. | |||||||
Voltage | Four-digit display, resolution 0.1V. | ||||||||
Electric current | Four-digit display | ||||||||
noise | ≤70dB (A) | ||||||||
Overload | 105% of rated current; disconnect delay 600s; 150% of rated current; 60s off delay; | ||||||||
Protection | Output overload protection, output overcurrent protection, output short circuit protection, overheating protection. | ||||||||
Cooling device | Forced fan cooling. | ||||||||
memory function | Output voltage, frequency preset memory automatically after completion, power cycle still keep the original preset value. | ||||||||
Preset function | In the standby state can be preset output voltage, output voltage frequency, output voltage, a floating percentage. | ||||||||
Dimensions (mm) | 378*171*360 | 360*520*500 | 430*630*520 | 480*800*600 | 520*1000*820 | ||||
weight | 38kg | 80kg | |||||||