bargain
add to cart| Input voltage: 1 (v) | Waveform distortion: 1 (%) | Frequency voltage regulator: 1 (%) |
| Output voltage: 1 (v) | Load voltage: 1 (%) | Circuit mode: SPWM switch |
| Type of load: resistive load | Customized processing: Yes | Efficiency: 1 (%) |
| Applications: computer equipment | Type: single phase inverter power | Model: AND220 |
| Output frequency: 1 (Hz) | Brand: ACS | Control mode: pulse-width modulation |
| Input frequency: 1 (Hz) |
(Product brief)
The power inverter is a mains and battery power into a continuous, clean AC power transducers, to provide computers and other power supply equipment of continuous AC power can be used to guard against instability and sudden power off of the mains. Also can prevent public power of various distortion, as power voltage declined, waves Chung voltage, pointed peak power and the broadcast frequency interference, the series inverse variable power designed for power plant, substation design, widely application Yu power system communications, monitoring, following electric protection and accident lighting, also can for Exchange lubricants pump, Exchange wind machine, pump, provides not continuous power and widely application Yu aviation space, financial system, Office Automation control, medical health, military research, all field.
(Main features)
1; Circuit compact; High efficiency; Earthquake preparedness;
2; Total isolated DC inverter technology; AC noise-free pure sine-wave output voltage;
3; Wide input voltage range; High voltage stabilizing precision; Environmental adaptability;
4; Inverter unit with microprocessor control; Sine pulse width modulation SPWM technique; Wave pure;
5, unique dynamic current control technology to ensure reliable operation of the inverter;
6; Overload capability; Can withstand the load power surge hit the computer;
7; Mitsubishi IGBT; Mitsubishi driver module; Ruby; Suzuki import filter capacitors;
8, with input over/under voltage, output over voltage, over temperature, short circuit protection. Protection, long service life
9; High-power static bypass switch; Can be converted automatically bypass the power supply overload; Switching time is short;
(Standard)
(GB7260-87 uninterruptible power supply equipment) (Q/01AK001-2005 program-controlled frequency power supply) (GJB181A-2003 powered aircraft characteristics) (GJB572-88 aircraft ground power supply characteristics and General requirements)
(Technical data)
Model | AND220-1010 | AND220-1020 | AND220-1030 | AND220-1050 | AND220-1100 | AND220-1200 | AND220-1300 | AND220-1500 | |||||||
DC input | Input rated voltage | 220VDC | |||||||||||||
Input rated current | 5A | 10A | 15.2A | 25A | 49A | 99A | 148A | 247A | |||||||
Input DC power supply range | 180-300VDC | ||||||||||||||
AC bypass input | Permissible input voltage range | 220V±15%VAC | |||||||||||||
Input rated current | 4.5A | 9A | 13.6A | 22.7A | 45A | 91A | 136A | 227A | |||||||
Bypass time | ≤4ms | ||||||||||||||
AC output | Rated capacity | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 20KVA | 30KVA | 50KVA | ||||||
Rated output power | 0.8KW | 1.6KW | 2.4KW | 4KW | 8KW | 16KW | 24KW | 40KW | |||||||
Rated output voltage and frequency | 220VAC, 50HZ | ||||||||||||||
Rated output current | 4.5A | 9A | 13.6A | 22.7A | 45A | 91A | 136A | 227A | |||||||
Output voltage accuracy | 220V±3% | ||||||||||||||
Output frequency accuracy | 50HZ±0.05 | ||||||||||||||
Waveform distortion (linear load) | THD≤±2% | ||||||||||||||
Dynamic response (load 0-100%) | 5% | ||||||||||||||
Power factor (PF) | 0.8 | ||||||||||||||
Overload capacity | 150%, 10s | ||||||||||||||
Peak factor (CF) | 3: 1 | ||||||||||||||
Inverter efficiency | 90% | 92% | |||||||||||||
Communication interface (optional) | RS232/485 | ||||||||||||||
Work environment | Dielectric strength (input and output) | 1500VAC 1 minute | |||||||||||||
Noise (1 m) | ≤50dB | ||||||||||||||
The use of ambient temperature | -10~50℃ | ||||||||||||||
Humidity | 0-90% (non-condensing) | ||||||||||||||
Use elevation | ≤2000 | ||||||||||||||
Mechanical dimensions | Vertical width * depth * height (mm) | 190*320*320 | 240*480*405 | 550*600*980 | 600*550*1400 | 1000*800*2260 | |||||||||
Rack width * depth * height (mm) | 482*405*133 | 482*405*178 | 482*420*222 | No | |||||||||||
Reference weight (Kg) | 18 | 30 | 40 | 60 | 150 | 260 | 360 | 700 | |||||||
Protection function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, and overtemperature protection. | ||||||||||||||