bargain
add to cart| Input voltage: 0 (V) | Waveform distortion: 0 (%) | Output voltage: 0 (V) |
| Frequency regulation: 0 (%) | Load regulation: 0 (%) | Custom processing: |
| Efficiency: 0 (%) | Applications: Laboratory | Type: Single-phase inverter power supply |
| Model: AND220 | Output frequency: 0 (Hz) | Brand: acsoon |
| Product Certification: CCC | Control mode: Pulse width modulation type | Input Frequency: 0 (Hz) |
(Introduction)
The inverter is a power mains and battery power converted into continuous, clean AC power conversion device, the power supply to the computer and other equipment that can be used to provide continuous AC power mains unstable preparedness and suddenly powered down. can also prevent various distortion of utility power, such as the supply voltage drops, surge, power spikes and broadcast frequency interference, the series inverter power supply designed for power plants, substation design, widely used in power system communication , monitoring, protection and emergency lighting, but also for exchange oil pump, AC fans, pumps and other offers uninterrupted power and are widely used in aerospace, financial systems, office automation, medical, military and scientific research.
(main feature)
1; Circuit compact; high efficiency; anti-vibration;
2; completely isolated inverter technology; no noise pure sinusoidal AC output voltage;
3; wide input voltage range; high voltage accuracy; environmental adaptability;
4; inverter unit uses microprocessor control; SPWM sinusoidal pulse width modulation technique; waveform pure;
5, unique dynamic current loop control technology to ensure reliable operation of the inverter;
6; overload capability; can withstand computer load power surge;
7; Mitsubishi IGBT; Mitsubishi driver module; ruby; Suzuki import filter capacitor;
8, with input over voltage, output over voltage, over temperature, short circuit protection full protection, long service life
9; high-power static bypass switch; overload can be automatically converted bypass; switching time is short;
(Performance standards)
(GB7260-87 uninterruptible power supply) (Q / 01AK001-2005 programmable frequency voltage power supply) (GJB181A-2003 aircraft power characteristics) (GJB572-88 aircraft ground power supply characteristics and general requirements)
(Technical Parameters)
model | AND220-1010 | AND220-1020 | AND220-1030 | AND220-1050 | AND220-1100 | AND220-1200 | AND220-1300 | AND220-1500 | |||||
DC input | Input rated voltage | 220VDC | |||||||||||
Input rated current | 5A | 10A | 15.2A | 25A | 49A | 99A | 148A | 247A | |||||
Permissible range DC power input | 180-300VDC | ||||||||||||
Mains Bypass input | Allowable input voltage range | 220V ± 15% VAC | |||||||||||
Input rated current | 4.5A | 9A | 13.6A | 22.7A | 45A | 91A | 136A | 227A | |||||
Bypass conversion time | ≤4ms | ||||||||||||
AC output | Rated Capacity | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 20KVA | 30KVA | 50KVA | ||||
Rated power output | 0.8KW | 1.6KW | 2.4KW | 4KW | 8KW | 16KW | 24KW | 40KW | |||||
Output rated voltage and frequency | 220VAC, 50HZ | ||||||||||||
Output rated current | 4.5A | 9A | 13.6A | 22.7A | 45A | 91A | 136A | 227A | |||||
Output voltage accuracy | 220V±3% | ||||||||||||
Output frequency accuracy | 50HZ ± 0.05 | ||||||||||||
Waveform distortion (linear load) | THD≤ ± 3% (resistive load) | ||||||||||||
Dynamic Response (0-100% load) | 5% | ||||||||||||
Power factor (PF) | 0.8 | ||||||||||||
Overload | 150%, 10s | ||||||||||||
Crest factor (CF) | 3: 1 | ||||||||||||
Inverter efficiency | 90% | 92% | |||||||||||
Communication interface (optional) | RS232 / 485 | ||||||||||||
working environment | Dielectric strength (input and output) | 1500VAC, 1 分钟 | |||||||||||
Noise Room (1 m) | ≤50dB | ||||||||||||
Ambient temperature | -10~50℃ | ||||||||||||
humidity | 0-90% (non-condensing) | ||||||||||||
Altitude | ≤2000 | ||||||||||||
Mechanical Dimensions | Vertical depth * width * height (mm) | 190*320*320 | 240*480*405 | 550*600*980 | 600*550*1400 | 1000*800*2260 | |||||||
Rack W * D * H (mm) | 482*405*133 | 482*405*178 | 482*420*222 | no | |||||||||
Reference weight (Kg) | 18 | 30 | 40 | 60 | 150 | 260 | 360 | 700 | |||||
Protection | Reverse input protection, input under-voltage protection, output overload protection, output short circuit protection, overheating protection. | ||||||||||||