bargain
add to cart| Input voltage: 0 (V) | Waveform distortion: 0 (%) | Frequency regulation: 0 (%) |
| Output voltage: 0 (V) | Load regulation: 0 (%) | Circuit mode: SPWM switching |
| Load Type: Rectifier load | Custom processing: | Efficiency: 0 (%) |
| Applications: Electronics Manufacturing | Type: Single-phase inverter power supply | Model: AND110 |
| Output frequency: 0 (Hz) | Brand: ACSOON | Product Certification: CCC |
| Control mode: Pulse width modulation type | Input Frequency: 0 (Hz) |
(Introduction)
Railway power inverter (110V input) for power plants, substations and high reliability requirements of the power supply to the new digital technology developed intelligent frequency inverter system adopts SPWM pulse width modulation technology, IGBT power modules and output isolation transformer, the power output of the inverter is a frequency stabilization, filter out noise, pure sine wave power interference from power fluctuations, low distortion, with a load capacity, load compatibility, DC Wide input voltage range of features, great to meet the needs of various electrical environment; perfect protection device improves system stability and reliability; human interface design, makes machines to communicate zero distance; inverter and between the PC via RS232 communication interface can be communication, allowing users to easily observed on the terminal at any time inverter working conditions, history, timely inverter control, at the same time via remote network monitoring capabilities, through the network The inverter can be remote, monitoring and management anytime, anywhere, truly unattended function, and the composition of the hot backup system to improve system reliability. In the stable above all design, AND110 series against change is undoubtedly your best choice.
(Applications)
Widely used in remote power systems, communications, carrier, monitoring, protection and emergency lighting.
(Features)
1. Compact circuit structure; high efficiency; anti-vibration;
2. The input and output electrical isolation inverter technology, EMC index is high;
3. Wide input voltage range; high voltage accuracy; environmental adaptability;
The inverter unit with microprocessor control; SPWM sinusoidal pulse width modulation technique; waveform pure;
5. The unique dynamic current loop control technology to ensure reliable operation of the inverter;
6. overload capacity, can withstand computer load power surge;
7. Mitsubishi IGBT; Mitsubishi driver module; ruby; Suzuki import filter capacitor;
8. With input over voltage, output over voltage, over temperature, short circuit protection full protection, long service life
9. High-power static bypass switch; overload can be automatically converted bypass; switching time is short;
(The main technical parameters)
Model (AND110-) | 3010 | 3020 | 3030 | 3050 | 3100 | 3150 | 3200 | 3300 | |
Direct-current enter | Rated Capacity | 1KVA | 2 KVA | 3 KVA | 5 KVA | 10 KVA | 15 KVA | 20 KVA | 30 KVA |
Rated input voltage (VDC) | 110 | ||||||||
Input voltage range (VDC) | 90~150 | ||||||||
Mains bypass | Input voltage range (VAC) | 380±15% | |||||||
Enter the maximum phase current (A) | 1.5 | 3.0 | 4.5 | 7.6 | 15.2 | 22.7 | 30.3 | 45.5 | |
Switching time (mS) | ≤4mS | ||||||||
communicate with Export | Rated voltage (VAC) | 380V | |||||||
Rated phase current (A) | 1.5 | 3.0 | 4.5 | 7.6 | 15.2 | 22.7 | 30.3 | 45.5 | |
Rated frequency (Hz) | 50Hz | ||||||||
Overload | 120% 1 minute; 150% for 10 seconds; 200% 1 second | ||||||||
Voltage stability accuracy (VAC) | 380±1% | ||||||||
Phase imbalance | Phase 120 ° ± 2 °, the retardation (nominal 3% | ||||||||
Adapt to the load | No type restrictions; available with completely unbalanced load; but the capacitive and inductive load shall be applicable derating | ||||||||
Frequency stability and accuracy (Hz) | 50±0.04 | ||||||||
Waveform distortion (THD) | 3% (linear load) | ||||||||
Dynamic response (0-100%) | ≤20ms | ||||||||
Power factor (PF) | 0.8 | ||||||||
Inverter efficiency | 92% | ||||||||
Crest factor (CF) | 3: 1 | ||||||||
system | Continuous running time | Continuous operation | |||||||
Noise (dB1 meters) | ≤50 | ||||||||
Ambient temperature | -10~+50℃ | ||||||||
Altitude | ≤4000 meters (altitude higher than 1000 m with derating) | ||||||||
Communication Interface | RS232; RS485; SNMP card; dry node (optional) | ||||||||
The above data for the reference data, subject to change without notice.