
bargain
add to cart| Input voltage: 1 (V) | Waveform distortion: 1 (%) | Frequency regulation of: 1 (%) |
| Output voltage: 1 (V) | Load regulation: 1 (%) | Circuit mode: SPWM switching |
| Load Type: Rectifier load | Custom processing: | Efficiency: 1 (%) |
| Applications: Computer equipment | Type: sine wave power inverter | Type: AND |
| Output frequency: 1 (Hz) | Brand: ACS | Product Certification: CCC |
| Control mode: Pulse width modulation type | Input Frequency: 1 (Hz) |
Model: AND110 series
Category: Inverter
product description
AND110 series of sine wave inverter is the latest application-specific requirements for power systems, telecommunications systems and railway systems and designed a new generation of intelligent power inverter. Capacity from 0.5K-30KVA, this series of products with superb production technology, excellent performance, easy operation and easy maintenance make it a 19-inch rack ideal for power supply applications.
AND110 series of sine wave inverter Features
1, intelligent control - internal CPU control circuit, high-performance SPWM inverter, LCD panel display parameters at a glance.
2, the use of security worries - the output used frequency isolation transformer completely isolated, suitable for capacitive, inductive loads and other equipment.
3, intelligent RS232 communication - with BONON power monitoring software allows users to monitor real-time operational status of the inverter power supply.
4, the DC-side anti-irrigation noise small - professional noise reduction measures, the DC side of the anti-irrigation noise low, in line with the industry standard.
5. Perfect protection - with a battery undervoltage, overvoltage, overload, short circuit and a series of protection against failures caused by human action.
6, high reliability - static electronic bypass switch inside the machine, in the event of a power failure, it can provide AC output.
AND110 series of sine wave inverter technology data
model | AND110 series | |||
project | Communication dedicated 110V | |||
DC input | capacity | 0.5KVA-30KVA | ||
Rated voltage | 110V | |||
Allowable variation range | 92V-137V | |||
Relative harmonic content | (40mV | |||
AC input voltage | 165-275V | |||
frequency | 50Hz ± 10% | |||
AC output | AC output voltage | 220V±1% | ||
frequency | 50Hz ± 1% | |||
Waveform | Sine wave | |||
Dynamic characteristic | Load current 25% -50% -75%; mutations output; voltage variation ≤12%; response ≤6% | |||
Relative harmonic content | Input voltage and load current is rated a time when ≤6% | |||
Limit | 0.15∽0.5MHz, peak (79dB Mean (66dB; 0.5∽30MHz, quasi-peak (73Db mean (60dB | |||
Rated output efficiency | ) 85% | |||
Overload | The load current is automatically jumps to bypass 20s 120% -150% rated value, automatic recovery | |||
Protection performance | AC bypass power failure; DC input undervoltage; overload; failure; output short; passing temperature | |||
LCD | LCD Display | Display AC input; output voltage; frequency; DC input voltage; percentage of output power | ||
LED Display | Display AC input; bypass output; the inverter output; overload; DC undervoltage; fault | |||
Communication Interface | Intelligent RS232 communication interface | |||
surroundings | temperature | 0-40℃ | ||
Relative humidity | 20-90%, non-condensing | |||
Insulation resistance | Compliance with EN50081-1 / EN55022 | |||
Dielectric strength | Compliance with EN50081-1 / EN55022 | |||
Bypass conversion time | 0ms | |||
noise | (55dB | |||