add to cart| Input voltage: 1 (V) | Waveform distortion: 1 (%) | Frequency regulation of: 1 (%) |
| Output voltage: 1 (V) | Load regulation: 1 (%) | Circuit mode: SPWM switching |
| Load Type: Mixed loads | Custom processing: | Efficiency: 1 (%) |
| Applications: IT industry | Type: Three-phase inverter power supply | Model: AF60 |
| Output frequency: 1 (Hz) | Brand: ACS | Product Certification: CCC |
| Control mode: Pulse width modulation type | Input Frequency: 1 (Hz) |
110V / 60HZ / 5KVA three-phase inverter power supply is designed for the import and export of electrical products transformer voltage, frequency test power supply design and manufacturing, can provide world standard grid voltage and frequency, output voltage, frequency stepless digital adjustable waveform purity and stability, eliminate network interference, applicable to the export of electrical products voltage, frequency test; laboratory, measuring room for all kinds of sophisticated tests, and as imports 60Hz power supply device A F60 series was going to be electric power by the power conversion circuit changes. A power supply for the required voltage and frequency, its main feature is to provide a reliable pure sine wave power output, to harmonic distortion, frequency and voltage stability of the high rate. A F60 Series Power on the general load types without special requirements but taking into account the grid voltage fluctuations, can be adapted to resistive, inductive, capacitive, rectification and mixed load. Technical parameters given sample is rated state, under conditions of resistive load test at rated conditions, supply long run. load current crest factor, short-time overload and other factors, select the power frequency is appropriate margin should be left mixed load: frequency drift, waveform distortion, noise interference, harmonic interference, Jianbo pulse, voltage surges, brownouts , voltage sag.
110V / 60HZ / 5KVA three-phase inverter power supply Product Features:
1. The use of separate (stand-alone), output isolation power transformer structure, three-phase single-phase desirable use
2. The high-precision frequency stabilization; rapid adjustment knob voltage; frequency; available with load directly regulate online
3. The three-phase active power; frequency; high precision; strong anti-interference ability
The transient response speed, 100% load / unload, the regulator within 2ms response time
5. No radiation interference; containing a small harmonic components; and after special treatment; no interference
6. Unique instantaneous value control; small waveform distortion; high control accuracy
7. High efficiency up to 85%; wide loads; may be inductive; capacitive; resistive load
8. Provide world standard grid voltage; frequency; simulation tests of various electrical products
9. Output voltage: high-grade phase voltage 0 ~ 300V (line voltage of 0 to 520) continuously adjustable, low phase voltage 0 ~ 150V (line
Voltage 0 ~ 260V) continuously adjustable voltage can simulate the world
10. The independent electrical parameters of table show actual real-time measurement: Output frequency; output voltage; output power and; Output Current
Load power factor
11. Mitsubishi IGBT, Mitsubishi driver module; ruby; Suzuki import filter capacitor
(110V / 60HZ / 5KVA three-phase inverter power source performance standards)
(GB7260-87 uninterruptible power supply) (Q / 01AK001-2005 programmable frequency voltage power supply) (GJB181A-2003 aircraft power characteristics) (GJB572-88 aircraft ground power supply characteristics and general requirements)
(110V / 60HZ / 5KVA three-phase inverter power supply technology parameters)
model | AF60-13005 | ||
capacity | 5KVA | ||
Volume (L * W * H) | 660 * 400 * 700 (mm) | ||
grade | High-end industrial products | ||
working principle | IGBT / SPWM pulse width modulation | ||
AC input | Phase | Simplex | |
Voltage | 220V±10% | ||
frequency | 50HZ ± 5% | ||
AC output (Standard sine wave) | Phase | Phase four-wire | |
Voltage | Line voltage | Low-grade: 0-260V continuously adjustable, high-grade: 0-500V continuously adjustable | |
Phase voltage | Low-grade: 0-150V continuously adjustable, high-grade: 0-300V continuously adjustable Customers can request special custom | ||
Phase current | 13.8A (L) | ||
6.9A (H) | |||
frequency | 50/60 / 45-65HZ (continuously adjustable) or 400HZ / 300-500HZ (continuously adjustable) (can be customized) | ||
Frequency stability | ≤0.01% | ||
Load stability | ≤±1% | ||
Voltage regulation rate | ≤±1% | ||
Waveform distortion | THD≤ ± 3% (resistive load) | ||
Unbalanced | Phase 120 ° ± 2 °; phase difference (3% Rating | ||
Power Factor | 0.85 | ||
effectiveness | ≥85% | ||
Reaction time | (20ms | ||
Adapt to the load | No type restrictions, inductive and capacitive loads need to amount to use. | ||
Panel Displays | Digital display: Output frequency; voltage; current; power / power factor | ||
protective device | Input no-fuse switch; Output no fuse switch; overvoltage; overcurrent; overload; over temperature and short circuit protection and automatic alarm | ||
noise | (50dB | ||
Insulation reactance | 500Vdc 20MΩ or more | ||
Voltage insulation | 1800Vac / 5mA / 1 分钟 | ||
Cooling device | Forced air cooling fan | ||
Chassis Architecture | Three film surface quality, fine orange lines | ||
Electromagnetic Compatibility | Referring GJB151A-97, GJB152A-97 requirements | ||
Use of the environment | Operating temperature | -10~50℃ | |
Relative humidity | 0-90% (non-condensing) | ||
Altitude | 2000 meters | ||
Remark | a. Power according to the modular design, ease of maintenance replacement parts. b. Follow the on ship vibration test standards, strengthening anti-vibration, after the long-distance transport to ensure reliable performance. c. After the parameters debugging, still keep the original settings. d. Communication monitoring optional RS232 / 485 and other communications interfaces. e. according to the voltage, frequency and other parameters can be specially tailored to customer requirements. | ||