add to cart| Input voltage: 1 (V) | Waveform distortion: 1 (%) | Frequency regulation of: 1 (%) |
| Output voltage: 1 (V) | Load regulation: 1 (%) | Circuit mode: SPWM switching |
| Load type: inductive load | Custom processing: | Efficiency: 1 (%) |
| Applications: appliance manufacturing | Type: variable voltage variable frequency power supply | Model: AF60 |
| Output frequency: 1 (Hz) | Brand: ACS | Product Certification: CCC |
| Control mode: Pulse width modulation type | Input Frequency: 1 (Hz) |
30KVA45KVA variable frequency power supply / AC power supply failure of a key stop function, quick response reaction time ≤2ms strong overload capability, instantaneous current can withstand 3 times the rated current output frequency:... 40-499.9Hz logic programming refers to the wave set Output voltage 0-150V / 0-300V10 laps fine tuning.
30KVA / 45KVA inverter power supply / AC power supply
Three single out a single-phase series of variable frequency power supply / AC power supply three-phase input single phase output inverter power supply / AC power supply range: 500VA-120KVA30KVA45KVA variable frequency power supply / AC power supply goods and common features of a country's first transistor type inverter power supply experts ..., immunity can not be replaced (only the power transistors) .2 failure of a key stop function, quick response and strong reaction time ≤2ms 3 Overload capability, instantaneous current can withstand 3 times the rated current 4 Output frequency: 40- 499.9Hz logic programming refers to the wave set. 5 Output voltage 0-150V / 0-300V10 laps fine tuning. 6 Power module design patents, fast response for special load, high efficiency energy electrical parameter measurement accuracy of variable frequency power supply 7 : 8 voltage: ± 0.15% FS + 4COUNT; current: ± 0.2% FS + 4COUNT; 9 frequency:. ± 0.1%; Power: ± 0.3% FS + 4CIYBT 10 stable pure sine wave voltage, perfect protection and fault alarm display function 11 no fuse switch with input;. for fast protection and lock failure; an alarm; display failure; 12 electronic circuit instant voltage, over current, overload, input under-voltage, over temperature and short circuit.
The following is a 30KVA / 45KVA inverter power supply / AC power supply specialized spec sheet
Model (AF60) | 33030 / 45KVA | ||
Output Capacity (KVA) | 30KVA / 45KVA | ||
Circuit mode | IGBT / SPWM pulse width modulation mode | ||
AC input | Phase | Phase four-wire + G | |
Waveform | SINEWAVE | ||
Voltage | 380/220V±10% | ||
Frequency fluctuation | 47-63Hz ± 5% | ||
Power Factor | ) 0.85 | ||
AC output | Phase | Simplex | |
Waveform | SINEWAVE standard sine wave | ||
Voltage | Low | 0V-150V (L-N) | |
High-grade | 0V-300V (L-N) | ||
frequency | 40-499.9Hz continuous set step rate 0.1Hz | ||
Frequency stability rate | ≤0.01% | ||
Maximum current | H-grade (A) 240V | 125.0A / 187.5A | |
L low-grade (A) 120V | 250.0A / 375.0A | ||
Overall performance | Power regulation rate | (0.5% | |
Load regulation | (± 0.5% (linear load) | ||
Waveform distortion (THD) | (± 1 ~ 2% (linear full load) output pure sine wave stability criteria | ||
effectiveness | ≥90% | ||
Reaction time | ≤2ms | ||
Crest Factor | 3: 1 | ||
protective device | No melting line input switch, circuit instant over voltage, over current, overload, input under-voltage, over temperature & short circuit, fast protection and lock failure, warning that failure. | ||
Voltage | 4 yuan number, digital voltmeter. Resolution 0.1V | ||
Electric current | 4-digit, digital ammeter. Resolution 0.1A | ||
power | 4-digit, digital watt meter 0.1W | ||
frequency | 4 yuan, number of frequency meter, resolution 0.1Hz / Step | ||
Environmental and other | Insulation Resistance | DC500V≥20MΩ | |
Voltage insulation | AC1800V10mA / 1 分钟 | ||
Cooling device | High-speed variable frequency fan cooling, forced air cooling | ||
Operating temperature | 0℃-45℃ | ||
Relative humidity | 0-90% (non-condensing) | ||
Altitude | ≤1500m | ||
Size (H * D * W) mm without casters | 1040*950*610 | ||
Weight (kg) | About 330/450 | ||