bargain
add to cart
| ||||||||||||||
| Detailed description: | ||||||||||||||
Ji Song FT-101 Jacqueline Scott capacity density Tester: is my company according to GB/t 1479.2-2011-determination of bulk density of metal powder-part 2: Jacqueline Scott volume method instead of standard GB5060-85 (determination of apparent density of metal powder-part II: Jacqueline Scott capacity meter) powder apparent density measurement device was developed. Both of the reference to the international standards IS0 3923-2:1981{2nd part for determination of apparent density of metal powder: Jacqueline Scott volume). as provided in the basic structure and parameter requirements, its targets are in line with the provisions of the standard.Sampling: 3.1 Determination of when each powder apparent density, and should take at least 100cm 3Volume of sample, carried out by three. 3.2 Typically, powders-determination according to the receiving State, in some cases, the powder should be dry. But if the powder easy oxidation and drying in a vacuum or inert atmosphere. If powders contain volatile substances, is not allowed to dry Ji Song FT-101 Jacqueline Scott capacity density tester performance indicators: 1, Upper funnel Assembly: Material: 304 stainless steel; Top-caliber 112mm, bottom diameter PHI 30mm, total length: 30+850mm. screen: 1.18mm stainless steel mesh. 2, Fabric boxes: Square, built in four pieces of 1 mm thick stainless steel bezel. 3, Square funnel: 60 ° Cone, bottom diameter for 12.5mm*12.5mm. 4, Cylinders: Material: 304 stainless steel; Capacity of 25 ± 0.05 ml. 5, Size: 100 mm*160 mm*358 mm. Calculation of results: Metal powder to loose mass and volume from density, calculated as follows:
In the formula: ρas : Jacqueline Scott volume of measured bulk density of powder, g/cm3, M: the quality of metal powders, g; V: loose powder size, cm3. Take the arithmetic mean of the three results report the final results, to the 0.01g/cm 3. When measuring the difference between the results of more than three times the average of 1%, the results of its minimum and maximum values must be quoted. Jorge Rico instrument tip, and associated products FT-102A vibration hopper apparent density analyzer FT-100A tap density meter; Ji Song FT-101 Jacqueline Scott capacity density Tester, FT-102 Hall flow meter/bulk density Tester-stainless steel; FL4-1 Hall flow meter/powder flow Tester-brass
Note: specific data, please keep in touch with us, and related products.
Ji Song FT-101 Jacqueline Scott capacity density Tester: is my company according to GB/t 1479.2-2011-determination of bulk density of metal powder-part 2: Jacqueline Scott volume method instead of standard GB5060-85 (determination of apparent density of metal powder-part II: Jacqueline Scott capacity meter) powder apparent density measurement device was developed. Both of the reference to the international standards IS0 3923-2:1981{2nd part for determination of apparent density of metal powder: Jacqueline Scott volume). as provided in the basic structure and parameter requirements, its targets are in line with the provisions of the standard.Sampling: 3.1 Determination of when each powder apparent density, and should take at least 100cm 3Volume of sample, carried out by three. 3.2 Typically, powders-determination according to the receiving State, in some cases, the powder should be dry. But if the powder easy oxidation and drying in a vacuum or inert atmosphere. If powders contain volatile substances, is not allowed to dry Ji Song FT-101 Jacqueline Scott capacity density tester performance indicators: 1, Upper funnel Assembly: Material: 304 stainless steel; Top-caliber 112mm, bottom diameter PHI 30mm, total length: 30+850mm. screen: 1.18mm stainless steel mesh. 2, Fabric boxes: Square, built in four pieces of 1 mm thick stainless steel bezel. 3, Square funnel: 60 ° Cone, bottom diameter for 12.5mm*12.5mm. 4, Cylinders: Material: 304 stainless steel; Capacity of 25 ± 0.05 ml. 5, Size: 100 mm*160 mm*358 mm. Calculation of results: Metal powder to loose mass and volume from density, calculated as follows:
In the formula: ρas : Jacqueline Scott volume of measured bulk density of powder, g/cm3, M: the quality of metal powders, g; V: loose powder size, cm3. Take the arithmetic mean of the three results report the final results, to the 0.01g/cm 3. When measuring the difference between the results of more than three times the average of 1%, the results of its minimum and maximum values must be quoted. Jorge Rico instrument tip, and associated products FT-102A vibration hopper apparent density analyzer FT-100A tap density meter; Ji Song FT-101 Jacqueline Scott capacity density Tester, FT-102 Hall flow meter/bulk density Tester-stainless steel; FL4-1 Hall flow meter/powder flow Tester-brass
Note: specific data, please keep in touch with us, and related products.
|