Features: | In addition to electrostatic ion wind machine speed tests table | | Test object | XC-650S | | Test location | Determination of project | Test distance (front) | | 30CM | 60CM | 90CM | 120CM | | | | Left 25CM | + (秒) | 1.5 | 2.5 | 2.9 | 3.7 | | | | - (秒) | 2 | 2.9 | 3.3 | 4.2 | | | | Ion balance (v) | 3 | 3 | 2 | 2 | | | | Central | + (秒) | 0.9 | 2.1 | 2.5 | 3.4 | | | | - (秒) | 1.1 | 2.7 | 3.3 | 3.9 | | | | Ion balance (v) | 3 | 2 | 2 | 1 | | | | Right 25CM | + (秒) | 2.3 | 2.8 | 3.5 | 4.3 | | | | - (秒) | 2.7 | 2.9 | 3.9 | 5.1 | | | | Ion balance (v) | -3 | 1 | 1 | 2 | | |
| Technical parameters | | Working voltage: | 220VAC/50Hz or 11VAC/60Hz | | Current consumption: | 0.23A or 0.46A | | Operating temperature: | 0℃-50℃ | | Air volume: | 300-440 CFM | | Air space: | 550*1200 | | Outside dimensions: | D240*W660*H240 | | Net weight: | 7.5Kg |
| Speed test: | | Measurement distance | | Number of tests | 30CM | 60CM | 90CM | 120CM | | | | Central (M/S) | I | 2 | 1.8 | 1.3 | 0.8 | | | | II | 2.3 | 1.9 | 1.4 | 0.6 | | | | III | 2 | 1.8 | 1.2 | 0.7 | | |
| Speed test: | | Measurement distance | | | 30CM | 60CM | 90CM | 120CM | | | | | Left 25cm | 2.1 | 1.8 | 1.3 | 0.8 | | | | Centre | 2.2 | 1.9 | 1.4 | 0.6 | | | | Right 25cm | 2.1 | 1.8 | 1.2 | 0.7 | | |
Welcome to inquire, 18617045504 (Zhao). Mail q data price list. jackcyzhao@126. com |