Measurable process temperatures up to 375 ° F (191 ° C), and without the use of remote diaphragm seals or capillary
Accuracy of 0.25%, turndown ratio of 100: 1
Under high temperature applications, temperature effects and reduce response time
Sensing film head and the same board with the Model 3051C
model | Transmitter Type (choose one) |
TY3051HD TY3051HG | Differential pressure transmitters for high temperature process Gauge pressure transmitters for high temperature process |
Code | Pressure range (URL) (choose one) |
2 3 4 5 | 0-2.5 to 0-250inH 2 O (0-0.62 to 0-62.2kPa) 0-10 to 0-1000inH 2 O (0-2.48 to 0-248kPa) 0-3 to 0-300psig (0-20.7 to 0-2070kPa) 0-20 to 0-2000psig (0-138 to 0-13800kPa) |
Code | Export |
A M (1) | 4-20mA, with digital signal based on HART protocol Low power consumption, 1-5Vdc, with digital signal based on HART protocol (0.8-3.2Vdc output, with the option code C2) |
Code | Process connection Process flange material | Drain / vent | Flange joint |
|
2 7 (2) | SST SST | SST Hastelloy | SST SST |
|
Code | Process isolating diaphragms |
2 3 (2) 5 | 316L SST Hastelloy C-276 Tantalum |
Code | O-ring material |
A | Glass filled tetrafluoroethylene (TFE) |
Code | The process of filling |
D H N | D.C. 200 silicone oil An inert liquid Neobee M-20 |
Code | Sensing film head diaphragm material |
2 | SST |
Code | Sensing film head filled |
1 2 | Silicone oil An inert liquid (a halogenated hydrocarbon) |
Code | Housing Material | Conduit Entry Size |
|
A B C D J K L | Aluminum, polyurethane coating Aluminum, polyurethane coating Aluminum, polyurethane coating Aluminum, polyurethane coating SST SST SST | 1 / 2-14NPT M20 * 1.5 (CM20) PG13.5 G1/2 1 / 2-14NPT M20 * 1.5 (CM20) PG13.5 |
|
(1) Not for use in hazardous location certification option codes I1, N1, E4 and K6.
(2) comply with NACE MR 01-75 recommended materials.
Code | Options |
B5 B6
E5 I5 K5 C6
K6 (1) I1 (1) N1 (1) E8 E4 (1) E7 I7
L4
M5 M6
Q4 J1 (2) J3 (2) T1 (3) C1 C2 C4 (4) S4 (5) P1 P2 D3 D8
| Mounting brackets 2-inch pipe installation and panel mounting universal mounting bracket, carbon steel bolts 2-inch pipe installation and panel mounting universal mounting bracket, SST Bolts Hazardous Locations Certifications Factory Mutual (FM) Explosion-Proof Factory Mutual (FM) Intrinsically Safe and non-flammable joint certification Factory Mutual (FM) Explosion-proof and Intrinsically Safe Canadian Standards Association (CSA) Explosion-proof and Intrinsically Safe (Requires maximum voltage 42.4Vdc) CSA and CENELEC Explosion-proof and Intrinsically Safe BASEEFA / CENELEC Intrinsic Safety Certification BASEEFA N class certification CESI / CENELEC Explosion-Proof Japanese Industrial Standard (JIS) Flameproof Certification Canadian Standards Association (SAA) flameproof certification Canadian Standards Association (SAA) Intrinsic Safety Certification Flange and fitting bolts Austenitic 316 SST Bolts Header LCD meter for aluminum housing (only housing codes A, B, C) LCD meter for SST housing (only housing codes J, K, L) Other options Check data Only the local zero adjustment None of the local zero and span adjustment Transient protection terminal block Custom software configuration (with the completion of the contract CDS00806-0100-4001) 0.8-3.2Vdc output, with digital signal based on HART protocol (output only Code M) Analog output stage according to NAMUR recommendation NE43 1994 年 1 月 18 日 And integral orifice assembly is connected - refer PDS00813-0100-4686 Ordering Information Hydrostatic testing Cleaning for special applications 1 / 4-18NPT process connection (flangeless fittings) Ceramic Ball Drain / vent valve |
(1) does not apply to low-power Option Code M. (2) The local zero and span adjustments as standard, unless specified option code J1 or J3. (3) Not for use in hazardous location certification codes I1 or K6. (4) Pre-set at the factory to comply with NAMUR operation, can not be changed to standard operation in the field. (5) This option Maximum static pressure rating of 3000psi (20684kPa), applies only to non-factory assembly connected to the pipe, and is limited to the range 2345. |