Product Standards: The product according to GB1270 (rated voltage 35kV and below copper, aluminum plastic insulated power cables) standard production, while also based on user needs recommended by the International Electrotechnical Commission standard IEC, British Standards, German Standards and US standards.
Cable Type: YJV | YJLV | YJY | YJLY | YJV22 | YJLV22 | YJV23 | YJLV23 | YJV23 | YJLV23 | YJV33 | YJLV32 | YJLV33 | | | |
|
Scope:
This product is suitable for frequency rated voltage 3.6 / kV-26 / 35kV distribution lines to handle electric energy.
Use features:
• frequency rated voltage Uo / U is 3.6 / 6KV-26 / 35KV. • cable conductor to allow long-term maximum operating temperature is 90 ℃. • When short circuit (the longest duration of no more than 5s) of the conductor temperature does not exceed 250 ℃. • When the cable laying temperature should not be less than 0 ℃. • cable bending radius: not less than three-core cable 15 times the cable diameter; single-core cable of not less than 20 times the cable diameter. Select cable rated voltage • rated voltage of cables should be suitable for cable system operating conditions, with Uo / U (Um) KV representation. Uo- conductor cable designed for the rated power or frequency voltage between the metal shield; Rated power cable designed U- frequency voltage between conductors; Maximum 'highest system voltage' of Um- device can withstand. • recommends the following table with the three-phase system value Uo cables: U kv | Um kv | Uo * kv | Class A and B systems | C class system | 6 | 7.2 | 3.6 | 6 | 10 | 12 | 6 | 8.7 | 15 | 17.5 | 8.7 | 12 | 20 | 24 | 12 | 18 | 30 | 36 | 18 | - | 35 | 40.5 | 21 | 26 |
A class system - such systems when any one phase conductor in contact with the ground or earth conductor, can be separated in 1min and systems; Class B system - such systems include only single-phase ground fault condition of short-run, ground-fault time should not exceed 1h, but in any case, a maximum of 8h, the total annual duration of the earth fault does not exceed 125h; C class system - does not belong to class A, class B systems. Production range: model Type | Number of cores Nomber of cores | Rated Voltage Rated Voltage kV | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | Nominal cross section Nominal cross-section of conductor mm2 | YJV YJLV YJY YJLY | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 | 3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | YJV22 YJLV22 YJV23 YJLV23 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 | 3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | YJV32 YJLV32 YJV33 YJLV33 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 | 3 | 25-630 | 25-630 | 25-400 | 35-400 | 50-240 | 50-185 | 50-150 |
|