| product number | XY-105W | XY-102W | XY-100W |
| Maximum capacity | 110g | 110g | 110g |
| Reading accuracy | 0.005 | 0.002 | 0.001 |
| Resolution | 0.01% | ||
| Display | LCD LCD | ||
| temperature range | 40 ℃ -199 ℃ (adjustable) | ||
| time limit | 1-99 minutes (adjustable) | ||
| Temperature interval | 1℃ | ||
| Moisture measurement range | 0-100% | ||
| Pan size | Φ90mm | ||
| Calibration methods | External calibration | ||
| Data output | Standard RS-232 interface | ||
| physical dimension | 200 * 180 * 380mm | ||
| Heating Type | Halogen Halogen lamp | ||
| display method | Moisture content% dry weight and moisture content% | ||
| Voltage Power | 220V 50HZ 400W | ||
| product weight | 5.8KG | ||
Halogen Moisture Analyzer Caution:
1. Halogen Moisture Analyzer is used to measure the moisture content of the sample, for any other purpose may be personal injury and
Damage the instrument.
2. Be sure to read the instructions before use, do not meet the requirements under the environmental conditions.
3, Halogen Moisture Analyzer is only familiar with the nature of the sample and by trained professionals.
4, Halogen Moisture Analyzer for the three-plug power socket with a grounded, disconnect the instrument bans the use without a good grounding wire or grounded power source.
5, around the instrument should ensure that there is enough space to avoid heat accumulation and overheating.
6, since the instrument around the area around the heating unit becomes hot, do not place flammable materials around the instrument.
7, after the end of the test, because the sample itself and the heating unit and its container still very hot, so be careful when removed samples.
8, the heating and drying process, no ring heating element temperature reaches 400 ℃. Therefore, do not open or touch the heating unit. To fight
Open disconnect the power supply and wait until it is completely cooled.
9, for flammable or combustible materials, solvent-containing matrix, the matrix will produce flammable or explosive gases when heated, especially careful, because this
These samples may harm the human body or damage to the device. Therefore, in the determination of such samples should be low enough to make the operation of the heating temperature
Prevent the formation of flames or explosives, and wear goggles and other protective equipment. If the sample is not very understanding of the flammability test sample
The amount should be minimized. In this case, the instrument should be supervised, just in case, before experiments do your own risk analysis.
10, containing toxic elements of the matrix, and this matrix only under good ventilation conditions, heating and drying.
11, a matrix generating corrosive vapors when heated drying, when measuring sample of this matrix, because the steam condenses in the cooler housing portion
Sub-corrosive, it is recommended to reduce the sample weight.