bargain
add to cart
Multi-stage heating curve programming; (3 segments basic settings can also be customized according to customer needs multi-stage);
The heating time is accurate to 0.1 seconds;
Achieve a variety of operating parameters display;
Rich interface, can be directly incorporated into the RS485, Profibus , CANbus and other industrial bus;
Use PC (PC) software enables engineering machine remote monitoring;
Use the SD card directly recording device operating parameters;
Use status query software, data analysis, fault diagnosis function.
Interactive man-machine interface:

| model | DIH-25 | DIH-40 | DIH-60 | |
| Export | Rated output power KW | 18 | 25 | 45 |
| Maximum output power KW | 25 | 40 | 60 | |
| Duty rates | 100% | |||
| Output power adjustment range | 8~100% | 5~100% | ||
| KHz frequency range | 10~55 | |||
| enter | Input voltage V | 3*380 | ||
| frequency | 50Hz | |||
| Rated current A | 31 | 45 | 80 | |
| Rated apparent power KVA | 21.5 | 31 | 45 | |
| Maximum apparent power KVA | 27.5 | 45 | 60 | |
| Recommended Insurance A | 63 | 100 | ||
| cool down | Cooling water minimum flow | 10L / min | 12L / min | |
| Maximum cooling water inlet temperature | max. 35 ℃ | |||
| Cooling water pressure min / max | 4 / 6bar * | |||
| Cooling water -PH value | 7.0~9.0 | |||
| other | Ambient temperature | +5℃~+50℃ | ||
| Dimensions cm | 550 * 250 * 520 (host) 420 * 300 * 480 (extension) | 550 * 280 * 580 (host) 450 * 255 * 390 (extension) | 510 * 350 * 510 (host) | |
| Weight (kg) | 14.5 (host) /13.5 (ext.) | 35 (host) / 30 (ext.) | 40 (host) / 48 (Extension) | |