Description:
*EA16 16Amp half wave automatic voltage regulator can be used in genset parallel operation.
* It's compatible with Marelli, Caterpillar, Khenkikian, and Genaust avrs.
( ±0.5% Regulation
Suitable for brushless type generator Sensing Input 170~510 VAC
Can be used in Parallel Operation
16 ADC Current Output
EA16 Suitable Frequency 50/60 Hz , EA16-400Hz Suitable Frequency 400 Hz
Soft Start Voltage Ramping
Load CT Current Compensation, Analogue Voltage Input
| EA16 Specifications | |
| Sensing Input | Voltage 170~510 VAC single phase 2 wire |
| Frequency 50/60 Hz *EA16-400Hz : Frequency 400 Hz | |
| Power Input | Voltage 60~300 VAC single phase 2 wire |
| Output | Voltage Max. 90 VDC @ 240 VAC input Current Continuous 16A, Max. Intermittent 20A for 10 sec. Resistance Min. 6 Ohm @ 35 VDC |
| Voltage Regulation | ( ±0.5% (with 4% engine governing) |
| Voltage Build-up | Residual volts at AVR terminal ) 5 VAC |
| External Volts Adjustment | ±5% with 2 K Ohm 1 watt trimmer |
| Unit Power Dissipation | Max. 10 watt |
| Thermal Drift | 0.03% per °C change in AVR ambient |
| Under Frequency Protection | 55 Hz @ 60 Hz / 45 Hz @ 55 Hz (Adjustable) *EA16-400Hz : 360 Hz (Adjustable) |
| CT Current Compensation Input | 1A or 5A (Selectable) |
| Analogue Input | ±5 VDC ±10% AC @ ±3 VDC |
| Environment | Operating Temperature : -40~70 °C Storage Temperature : -40~85 °C Relative Humidity : Maximum 95% Vibration : 3.3G @ 100~2 KHz |
| AVR Controls Functions | VOLT : Voltage Adjustment STAB : Stability Adjustment U/ F*: To Set the U/ F Knee Point DROOP : To Adjust Droop TRIM : Analogue Input Adjustment (*U/ F: Under Frequency Protection) |
| Dimensions | 156.0 (L) x 106.0 (W) x 43.0 (H) mm |
| Weight | 450g ±2% |