New Design Floor Standing 19" Network Cabinet

New Design Floor Standing 19" Network Cabinet

bargain

add to cart
Model NO. WB-EZxxxx15B
Usage Network Integration System
Fan Number Four
Certification CE, ISO, RoHS
Structure 19 Inches Inernational Standard
Material SPCC Cold Rolled or Eg Steel
Certifications CE. RoHS. SGS, ISO
Package Assemble or Disassemble
Trademark Webitelecomms
Specification ISO9001: 2008, CE, RoHS, SGS
HS Code 8517709000
Type Network Cabinet
Installation Vertical
Capacity 18~47u
Condition New
Color Black,Grey or Customized
Thickness Mounting Profile 2.0mm. Others 1.5mm
Static Loading 300-500kgs
Fans 2 or 4
Transport Package Carton Wooden Case
Origin Ningbo China.

Features

This cabinet is intended for installation monitor and telecommunication devices and their distribution systems.

19' rack mountable, Easy using structure - possible of max the load capacity up to 500KG.500KG.

Front & back door earthing.hing.hing.

Widely used for scurity and telecom devices.

Doors

Front glass door with vented door frame - swing handle lock.

Back solid metal door with small cylinder lock.

Removable side panel , optional lock.

Accessories

Fan fixed to cabinet top directly (2 or 4 )

4× position-adjustable 19 ' mounting rail.unting rail.g rail.

300KG capacity wheels and adjustable feet.

20 sets of extra M6 caged screws.

Cable entrance

Top - 1 * 400×50mm rectangle cable entrancentrancentrance

Bottom - 4* 350×50mm rectangle cable entrancentrancentrance

Can ask for more...

Package

Disassembled packing save 60% volume , allows for convenient stocking.

Neutral carton box packed

Plywood pallet for options

= Varies specification upon customers' special requirements=

Size suggestions

Width: 600,800 mm

Depth: 600,800,1000,1200 mm

Height: 12U, 17U, 22U, 27U, 32U, 37U, 42U, 47U

Customized size is available

Standard and Materials:

Comply with

ANSI/EIA,RS-310-D;IEC297-2;DIN41491:PART1;DIN41494:PART7;GB/T3047.2-92 standard and ETSI standard.

Surface Finish:Degrease, acid pickling, rust prevention and parkerizing,pure water cleaning, static electricity powder coating


Materials:SPCC cold rolled steel or EG steel

Thickness:Mounting profile:1.8mm,others: 1.00mm to 1.20mm

Cabinet Bearing capacity: 300-500KG

IP degree: IP-20


Body color:RAL9004(black);RAL7035(grey),etc

1 × SAMPLE is even available.ilable.ilable.

NO.

Item

600 wide

800wide

Materials

Treatment

Note

1

Frame

2

2

1.0mm SPCC steel

Powder coating

2

Front Door

1

1

1.0mm SPCC steel

/

metal border

3

Side Door

2

2

1.0mm SPCC steel

Powder coating

Removable

4

Back Door

2

2

1.0mm SPCC steel

Powder coating

5

Lock

2

2

/

/

Handle Lock

6

Top cover

1

1

1.0mm SPCC steel

Powder coating

7

Rear door panel

1

1

1.0mm SPCC steel

Powder coating

8

Fan unit

1

1

1.0mm SPCC steel

Powder coating

9

Ac fan

2 or 4

2 or 4

/

/

D﹥800,4 pcs pcs

10

Bottom panel

1

1

SPCC T=1.0

Powder coating

Optional parts

11

Earthing cable

1

1

Y/G cable

/

25 cm

12

Castors tray

4

4

SPCC T=2.0

Powder coating

13

Castors

4

4

/

/

14

Ajustable feet

4

4

Steel

Brass plated

M12

15

Mounting angle

2

2

SPCC T=1.2

Powder coating

16

19inch rails

4

4

SPCC T=1.8

Powder coating

17

Vertical C/M

/

2

SPCC T=1.2

Powder coating

Only for 800 W

Optional Accessories::

1. Fixed shelf (Recommending)

2. Sliding shelf

3. Cable management

4. Patch panel

5. PDU (Recommending)

SAMPLE Show____600*600 22U

Front view



Back view

Side view

Disassemble Packing

We take great commitments to photograph products indeed without any cheating and plagiarism!

Special Packing (Optional)

Model W×D×H mm;D×H mms;H mm;D×H mm U Model W×D×H mm;D×H mms;H mm;D×H mm U
WB-EZ661815B 600×600×903600×903es;903600×903 18U WB-EZ663215B 600×600×152500×1525s;152500×1525 32U
WB-EZ681815B 600×800×903800×903es;903800×903 18U WB-EZ683215B 600×800×152500×1525s;152500×1525 32U
WB-EZ691815B 600×900×903900×903es;903900×903 18U WB-EZ693215B 600×900×152500×1525s;152500×1525 32U
WB-EZ601815B 600×1000×903000×903es;903000×903 18U WB-EZ603215B 600×1000×152500×1525s;152500×1525 32U
WB-EZ662215B 600×600×108100×1081s;108100×1081 22U WB-EZ664215B 600×600×197000×1970s;197000×1970 42U
WB-EZ682215B 600×800×108100×1081s;108100×1081 22U WB-EZ684215B 600×800×197000×1970s;197000×1970 42U
WB-EZ692215B 600×900×108100×1081s;108100×1081 22U WB-EZ694215B 600×900×197000×1970s;197000×1970 42U
WB-EZ602215B 600×1000×108100×1081s;108100×1081 22U WB-EZ604215B 600×1000×197000×1970s;197000×1970 42U
WB-EZ662715B 600×600×130300×1303s;130300×1303 27U WB-EZ664715B 600×600×219200×2192s;219200×2192 47U
WB-EZ682715B 600×800×130300×1303s;130300×1303 27U WB-EZ684715B 600×800×219200×2192s;219200×2192 47U
WB-EZ692715B 600×900×130300×1303s;130300×1303 27U WB-EZ694715B 600×900×219200×2192s;219200×2192 47U
WB-EZ602715B 600×1000×130300×1303s;130300×1303 27U WB-EZ604715B 600×1000×219200×2192s;219200×2192 47U


OPERATION CONDITIONS

• Operation environment:nment:nment:

- Office,

- The cabinet is not intended for outdoor installations and for installations in environment that can influence negatively the functionality of the cabinet and the mounted devices (e.g. environment with danger of explosion or humid and wet surroundings).


• Must be protected against:ainst:ainst:
- Mechanical damage
- Improper handling
- A different usage than the cabinet is intended for
• Improper handling is especially:ially:ially:
- Overloading (maximum recommended load exceeding)
- Device installation that can influence negatively operation and function of the cabinet or the installed equipment
- Change of the construction or design of the cabinet

INSTALLATION OF THE CABINET

• To ensure the maximum recommended load, it is necessary to distribute the load equally.ually.ually.
• Place the cabinet on a flat floor and adjust any differences using the levelling feet. feet. feet.
• To avoid dust penetration in the case where cables lead through some of the cable openings, it may be sealed with a blanking panel with a brush or secured by a plastic frame (both can be purchased from us).m us).m us).

ENVIRONMENTAL PROTECTION

• All parts are made of recyclable materials and after decommissioning the cabinet, it must be disposed of according to relevant regulations.tions.tions.

CERTIFICATE AND CONFORMITY

• This product is fully in accordance with CE & RoHS.amp; RoHS.amp; RoHS.