LED Microcomputer Temperature Controller for Control Accuracy 0.1degree (HC-211M)

LED Microcomputer Temperature Controller for Control Accuracy 0.1degree (HC-211M)

50+
8.5-10.3 USD

add to cart
Model NO. HC-211M
Display Type LED
Type Temperature Controller
Control Type Digital
Specification ISO CE ROHS TUV UL
HS Code 9032100000
Certification CE, UL, RoHS, CCC, ISO, TUV, GB
Control Accuracy 0.1degree
Usage Air Conditioner, Refrigerator, Drying Equipment, Ventilation, Air Purifier
Material Plastic
Origin China

Applications:
Refrigeration industry(freezers, refrigerators, , Cold stores, cold chain, iceboxes, cooling towers, water coolers, oil coolers, cold water chillers, water chilling units etc.)
HVAC industry (Heating Ventilation Air Conditioning)
Pet industrial: Aquariums, fish tanks, terrariums, seafood machines, Vivariums, Paludariums, Incubators etc.
Medical thermostatic equipment (for blood, drugs, Pharmaceutical etc.)
Food processing (Brewing, Abattoirs etc.), Food Wholesale, Food Retail (Hypermarkets, Supermarkets, Convenience Stores, Food Shops, Charcuteries, Delicatessens etc.)
Solar water-heating system central controller
Sauna room, foot bath, foot sauna, foot massager etc.
Wine production, wine cabinet, display cabinet etc.
Catering (Hotels, Restaurants, etc.)
Agriculture
Automobile
Photography
Process control
Laboratory, Chemical
Greenhouses, cultivating-houses
Ice-skating rinks
Energy management
Other industries need temperature measuring and controlling
Features
LED display
Best cost-effective
Traditional design
Control Accuracy 0.1degree
Parameters:
Temperature measuring and controlling range: -40~110°Cdeg;Cdeg;C
Relay capacity of Compressor options: 5A or 10A; 30A(different price)
Power options: 220VAC, 110VAC, 12VAC/DC
Input: 1 NTC sensor; sensor wire: 2m(standard)
Accuracy: ±1°C; Resolution: 0.1°Cution: 0.1°Ceg;Cution: 0.1°C
Consumption: ≤3We;3We;3W
Cut-out size: 71×29(mm);29(mm);29(mm)
Ambient requirements: temperature: -10~60°C; humidity: 20~85% (No condensate)sate)sate)
Control Accuracy 0.1degree
Alarm output (It is the difference compare with RC-116M)
Friedly Reminder:
We can provide customized service for all of our products with reasonable price.

Code
Function Setting range Default Unit
F0 Mode option
C: refrigeration
H: heating
C /
F1 Differential 1~15 5 °Cdeg;Cdeg;C
F2 Lower Temp. limit -40~setting Temp. -40 °Cdeg;Cdeg;C
F3 Upper Temp. limit Setting Temp.~110 110 °Cdeg;Cdeg;C
F4 Temp. calibration -7~7 0 °Cdeg;Cdeg;C
F5 Compressor delay 0~7 1 Min.
F6 Lower Temp. limit -40~setting Temp. -40 °Cdeg;Cdeg;C
F7 Upper Temp. limit Setting Temp.~110 110 °Cdeg;Cdeg;C