Model NO. DC04-485
Usage Access Controller, Access Machine
Name TCP/IP 4 Door Access Control
Case Size 273mm * 228mm * 65mm
Circuit Board Power Consumption Less Than 100mA
Quantity of Reader 4PCS
Trademark Techcrepower
Origin China
Type Card
Model Number DC04 TCP/IP 4 Door Access Control
PCB Board Size 160mm Long * 106mm Wide
Power Supply 12VDC 4-7A
Means of Communication TCP/IP 10m/100m Self Adaptive, Webserver
Control Gate Output Relay 4pair
Specification CE, FCC
Product Introduction
HUAKE Access Control Panel provide the solution for powerful combinations of access control and alarm monitoring within off-line networks.The user-friendly Access software programs the system within a few minutes, from a non-dedicated PC.Access Software provides numerous access control and alarm monitoring features:Expiry date for clubs, automatic activation, interlock between two doors, time zones, supervision, anti-passback, activity reports...Each alarm input is programmable:Operating mode (NO or NC), time zones, local reflex (activation of outputs according to input status).Specific alarms are triggered according to the number of unsuccessful attempts, the time limit for door closing (door alarm), the duress code...Whenever required, the data stored in the controllers is transferred to the computer and activity reports are printed.Each controller works independently and keeps its own database.
Parameter index:
PCB board size:160mm long * 106mm wide
Case Size:273mm * 228mm * 65mm
Powersupply:12VDC 4-7A
Circuit board power consumption:Less than 100mA
Reader Input Format:Wiegand 26 (compatible with all readers under the agreement, such as Motorola, HID, EM, Mifare one, etc.).
Means of communication:RS232 RS485 jumper-free adaptive 9600 baud
Function Description:Can control four doors, enter via card swiping and exit via button
Quantity of reader:4PCS
Can control the gate output relay:4pair
Open delay time:1-600 seconds adjustable
Maximum number of connections:N * 256 PCS (N denotes the q'ty of computer serial port, support 256PCS serial port)
Operating temperature:-40 to 70 degrees Celsius
Run Humidity:10-90% RH, non-condensing
Signal output communication format and baud rate:RS232 RS485 adaptive self-test bus architecture, 9600 baud
User registration card q'ty:20, 000 cards Permissions
Record the number of offline storage:100, 000 records
Power failure protection measures:High-speed flash memory design, and never lose data
Max distance between reader to the controller:100 meters, suggest within 80 meters, Max distance for the bus line:1200 m, suggest within 1000 m, with expansion equipment the bus line can reach up to 3000 meters