add to cart| Model NO. | Cat7-utp |
| Conductor Material | Copper |
| Type | Cat 7 |
| Conductor | Solid Bare Copper |
| Insulation | HDPE |
| Trademark | Webitelecomms |
| Origin | Ningbo, China |
| Application | Local Communication Cable, Coaxial Cable, LAN Cable |
| Cover Material | PVC |
| Certification | CE, ISO, RoHS, CCC |
| AWG | 23 |
| Jacket | PVC |
| Specification | CE RoHS |
| HS Code | 5404190090 |
CAT7 CABLE
0.585mm BC+1.50mm FOAM PE+al foil for every pair+overall shield+drain wire+ braid+LZSH PVC jacket, orange
CAT7 CABLE
CABLE SFTP CAT7
CAT7 SFTP CABLE
0.585mm BC+1.50mm FOAM PE+al foil for every pair+overall shield+drain wire+ braid+LZSH PVC jacket, orange
1. SPECIFICATION
1) CONDUCTOR
* Raw material of the conductor: solid bare copper
* Conductor Dia.: 0.585±0.003mm (23AWG) (23AWG) (23AWG)
2) INSULATION
* Raw material of the conductor: F-PE
* Quantity:4 twisted pairs
Blue/white-blue; Green/white-green;
Orange/white-green; Brown/white-brown;
* Insulation Dia. : 1.45±0.005mmn;0.005mm;0.005mm
* Average thickness: 0.4325 mm
Minimum point thickness: 0.43mm
3) TWISTED PAIRS SCREEN: Aluminum foil
4) OVERALL SCREEN
* Raw material of the screen: 96/0.10mm TC wire braiding
* Coverage rate:≥40%e;40%;40%
5) JACKET RIP CORD: Nylon thread
6) SHEATH
* Sheath material: LSZH or PVC
* Nominal Dia.: 7.5 ± 0.2mmmn; 0.2mmn; 0.2mm
* Average thickness: 0.65mm
* Minimum point thickness: 0.55mm
2, Mechanical Properties
Conductor insulation material: halogen free Foam/Skin material
Cable jacket material: halogen-free, flame-retardant material
Application area: dray as well as humid rooms
Temperature (moved): 0°C to 50°Co 50°Cg;Co 50°C
Operating temperature: -20°C to +60°C+60°Ceg;C+60°C
Min. bending radius for one-time bending: 4×O.D.mes;O.D.es;O.D.
Min. bending radius during installation: 8×O.D.mes;O.D.es;O.D.
3, Electrical properties
Loop impendence: 130 W/km
Highest impendence difference: 2%
Insulation resistance ﹥5000 MW x kmx km
Impendence Z0at 1 500MHz: 100 W ± 15%usmn; 15%smn; 15%
Impendence Z0at 1 350MHz: 100 W ± 18%usmn; 18%smn; 18%
Impendence Z0at 1 600MHz: 100 W ± 25%usmn; 25%smn; 25%
Surface transfer impendence: < 100 MW per Meter at 10MHz0MHz
Earthing symmetry db/BZL = 1000m ﹥ 46dB at 64kHz4kHz
Earthing symmetry db/BZL = 100m ﹥ 40dB at 1MHz 1MHz
Earthing symmetry db/BZL = 100m ﹥ 20dB at 100MHz0MHz
Mutual capacitance: 43pF/m
Highest earthing-coupling: 0,001MHz: 1000 pF/km
Propagation speed at ﹥ 10MHz (NVP*c): 0,79c,79c
Signal propagation delay ﹥10MHz: 4,2ns/m2ns/m
Skew: <25ns/100m/100m