Product parameters:
'Product Details'


Radial seismic stainless steel pressure gauge is a series of seismic stainless steel pressure gauge commonly used in a type of installation (or structure), the instrument directly installed in the measuring equipment or pipeline to facilitate the operator to observe the pressure changes in the table filled with damping Liquid and the installation of damping devices, so that the pressure gauge to play a shock absorption, the role of earthquake, to adapt to severe vibration environment, resistant to pulsating media and impact load. For corrosive gas environment, can detect strong corrosive medium pressure Vacuum, pressure gauge instructions stable and clear. Widely used in petroleum, chemical, mechanical, metallurgical and other industrial sector pressure measurement.
Technical Parameters:
model | YN-50BF | YN-60BF | YN-75BF | YN-100BF | YN-150BF | |||
Nominal diameter (mm) | 50 | 60 | 75 | 100 | 150 | |||
Joint thread | G1 / 4; G3 / 8; G1 / 2; NPT1 / 4; NPT1 / 2, etc. | |||||||
Accuracy class (%) | 2.5 | 1.6 | ||||||
Measuring range (Mpa)
Psi bar kg / cm2 kpa mmHg can be customized | - 0.1~0; - 0.1~0. 06; -0.1~0. 15; -0.1~0. 3; -0.1~0. 5; -0.1~0. 9; -0.1~1.5; -0.1~2.4; | |||||||
0~0. 1; 0~0. 16; 0~0. 25; 0~0. 4; 0~0. 6; 0~1.0; 0~1.6; 0~2.5; 0~4.0; 0~6.0; 0~10; 0~16; 0~25; 0~40; 0~60; 0~100; 0~160; 0~250 | ||||||||
Ambient temperature (℃) | -25 ° C to 70 ° C; and -40 ° C to 70 ° C | |||||||
structure type | Axial with front (ZT); Clamp mounting (K) | |||||||
Seismic rating | V. H. 4 | |||||||
Implementation of standards | JB / T6804--2006 | |||||||
Degree of protection | IP65 | |||||||
Case material | 304SS | |||||||
Connector material | 304SS; |
| ||||||
|
|
|
|
|
|
|
| |
Use and Ordering Information:
The main components for the 316 material.
Stainless steel shock pressure gauge does not apply to the outside of aerobic, chlorine, nitric acid and hydrogen chloride and other strong oxidizing environment.
Please specify the name of the order, model, the interface thread and measuring range.
The use of the ambient temperature is too high, the instrument indicates the value does not return to zero, fine needle can be used in the instrument rubber plug on a small hole, so that the instrument cavity and the atmosphere can be communicated.
'part of the product'





Contact information
Address: No.36-6, Fengxiang North Road, Beitang District, Wuxi
Tel: 0510-85886598 82328671
Sales QQ: 2905045712
Technology QQ: 1870947388
Sales Manager: QQ: 2468412893
Sales Manager Mobile: 15861670938
Changzhou Branch Tel: 0519-88197617
Fax: 0510-85886598 82328671
Technical Services: 13961787023
E-mail: 13961787023@163.com