Technical Parameters
| parameter | specification | | Measuring range | Relative pressure: maximum 0 ~ 250MPa minimum 0 ~ 200Pa | | Absolute pressure: the largest 0 ~ 10MPa minimum 0 ~ 10KPa | | Accuracy class | 0.5 level 0.25 optional | | Temperature effects | Tk ≤ ± 2% FS / K | | stability | Better than 0.2% FS / year | | Position influence | The mounting position does not affect the zero point | | Allowable temperature | Medium temperature: -10 ~ 70 ℃ | | Ambient temperature: -20 ~ 60 ℃ | | Storage temperature: -30 ~ 80 ℃ | | Degree of protection | IP65 | | Adjustment range | Zero adjustment range ± 10% | | Full scale adjustment range ± 20% | | Power supply | 12-30V DC | | output signal | 4 ~ 20mA DC (analog, two-wire system) | | 1 to 5V DC, 0 to 5V DC , 0 to 10 V DC (Analog, three-wire system can be customized) | | Wiring lead-out mode | Can be derived from any one of the export, it is recommended to use the smallest φ7.5 industrial cables as a lead for sealing, lead-out connector for the general cable connector M12 × 1.5, do not lead end sealed with end caps | Refer to the documentation for the electrical wiring XYB series of diffused silicon pressure transmitter selection table XYB - diffusion silicon pressure transmitter series General purpose aluminum housing 2088Ex flameproof aluminum shell 2088A exquisite stainless steel series 2088B General aluminum shell liquid level series 2088C aluminum housing differential pressure series No code or E1: 4-20mA ;Current transmission output, two-wire system E2: 0-10mA current transmission output, three-wire system V1: 0-5V; V2: 1-5V; V3: 0-10V; V4: 0.5-4.5V voltage transmission output, three-wire system S: HART + 4-20mA HART communication protocol output Y: User-defined signal output No code: M20 * 1.5 threaded connection ML: M20 * 1.5 Diaphragm threaded connection MF: DN25 diaphragm flange connection MK: 1.5 "Sanitary Clamp Flange Y: User-defined connection type M1 0~100% Pointer table M2 LCD LCD display table M3: LED digital display table M4: Intelligent display table P1: 0.25; P2: 0.4; P3 or without code: 0.5; P4: 1.0 accuracy class Pressure type: No code: gauge pressure A: absolute pressure Measuring range: -100KPa-0 ~ 6MPa 0-20KPa ~ 100MPa interval selection For example, model example: XYB-2088P2 0 ~ 35Kpa. Model explained as follows Diffused silicon-type pressure transmitter transmission output 4-20mA; threaded connection M20 * 1.5; accuracy of 0.4; Pressure type gauge pressure (zero point and atmospheric communication), measuring range 0-35KPa. If you have any questions, please contact us at 0510-85886598 |