Product parameters:








Operating temperature | -20 ° C to + 50 ° C |
storage temperature | -40 ° C to 70 ° C |
Relative humidity | 10%~90% |
Atmospheric pressure | 86 to 106 kPa |
Environmental noise | ≤ 60dB |
Transmitter Specifications:
Injection method | 480Hz, 7.7KHz, 31KHz and 61KHz |
Induction mode | 31KHz, 61KHz |
Clamping method | 31KHz |
Fault finding | 8 / 480Hz composite frequency |
The output voltage | 0-400Vp-p changes according to insulation |
Output waveform | Sine wave |
power supply | 11.1VDC 4.4AH lithium battery |
Maximum output power | 10W |
Receiver Specifications:
Power consumption | <1.0W |
power supply | Lithium battery with |
Maximum test line depth | 5 meters (under normal circumstances) |
Test line buried depth error | ± 0.05h ± 5cm (h is the buried depth of pipeline) |
Test line routing error | Lt; |
Use injection method to test pipeline routing and buried depth effective length | Not less than 10Km (under normal circumstances) |
Using Induction Method to Test Line Routing and Buried Effective Length | Not less than 3Km (under normal circumstances) |
Use the clamp method to test the route route and the effective length of the buried depth | Not less than 6Km (under normal circumstances) |
Insulation fault finding | The insulation deteriorates from short circuit to 2MΩ |