Product parameters:

Tips: the above price is for reference only, please call or Want to consult, thank you cooperation!



advantage: Small size, light weight, high anti-interference, accurate detection, easy to operate

'Characteristic'
1, large-capacity built-in lithium battery, intelligent fast charging, no manual control;
2, DC power supply and AC power supply can automatically switch;
3, the equipment used in all high-interference lines, especially for urban census and maintenance of the pipe network.
4, the instrument automatically protects the ad hoc function to overcome the fatal weaknesses of similar products.
5, the instrument line modular design, three anti-design, improve the instrument's field life and reliability.
'Main Specifications'
1, the transmitter's technical parameters:
① Output power:> 25W, automatic adjustment
② transmit signal mode: low-frequency modulation signal
③ Output impedance matching: 0-100Ω, automatic matching
④ launch distance: 0.05-7Km, can gradually move to 7Km outside
⑤ work power: 12.6V large capacity built-in lithium battery 8800mAh
⑥ working temperature: - 20 ℃ ~ +50 ℃
⑦ Weight: 2.8Kg (with battery)
⑧ Dimensions: 255 × 225 × 100mm
2, the probe instrument technical parameters:
① sensitivity: 0.1mv;
② sounding range: ≤ 7m;
③ work power: 12.6V lithium battery 2200mAh;
④ working temperature: - 20 ℃ ~ +50 ℃
⑤ Weight: 0.6Kg (with battery)
⑥ Overall dimensions: 165 × 145 × 68mm
3, the detector technical parameters:
① leak detection accuracy: ≥ 0.25mm2
② position deviation: < 10cm
③ work power: 12.6V lithium battery 2200mAh;
④ working temperature: - 20 ℃ ~ +50 ℃
⑤ Weight: 0.6Kg (with battery) ⑥ Dimensions: 165 × 145 × 68mm
'Detection principle and method'
Probing, direction finding, sounding principle
The transmitter sends a specific electromagnetic wave signal to the underground pipe and determines its position, direction and depth by detecting the magnetic field of the underground pipeline.
Leak detection principle: the transmitter to the underground pipeline to send a specific electromagnetic signal in the underground pipeline coating damage point and the earth to form a loop, and radiation to the ground, above the damage point is a strong radiation signal, according to this principle to find the pipeline Corrosion point of the coating.
Leak detection method: We use the 'human capacitance' method. It is to do with the human body sensor detector components along the pipeline to detect, when the detectors went near the leak, the detector began to react, Just above, the speaker of the sound, the value shows large, so as to accurately find the leakage point.